Owner manual

00
REPLACE SYSTEM MASTER
CODE
(Default setting is 0000)
Master Code is used to log on to
programming mode, not to unlock
door or gate.
01
CHANGE TALK TIME
(Default setting is 090 Seconds)
Minimum setting is 10 seconds and
Maximum setting is 240 seconds.
Talk Time between the tenant and
visitor. The talk time is also a
hang-up time.
02
OPEN INTERVAL RELAY 1 and
RELAY 2
(Default setting is 012 Seconds)
Minimum setting is 04 seconds and
Maximum setting is 99 seconds.
Unlock Time for Door 1 and Door 2.
Step 1 Log on to programming mode (see section 3.1). The display shows
Step 2 Enter Function code 00, then press #, the display shows
Step 3 Enter the new 4-digit Master Code then press # the display shows
If you press
*
the display shows
Ignore the message, and your existing Master Code will remain in the system.
Step 4 Select another Function Code to program different field from the table or
press
*
to exit the programming mode and the display shows
Step 1 Log on to programming mode (see section 3.1). The display shows
Step 2 Enter Function code 01, then press #, the display shows
Step3 Enter the talk time (10-240 seconds) then press #, the display shows
Step 4 Select another Function Code to program different field from the table or
press
*
to exit the programming mode.
Step 1 Log on to programming mode (see section 3.1). The display shows
Step 2 Enter Function code 02, then press #, the display shows
Step 3 Enter 1 for relay 1 (door 1) or 2 for relay 2 (door 2) then press #, the
display shows
Pach and Company Chapter 3 Page 13
AeGIS NPB9000 Series PROGRAMMING 05/01/02
FUNCTION CODE LOCAL PROGRAMMING
SELECT PROGRAM
ENTER: _ _ PRESS #
MASTER CODE: 0000
NEW: _ _ _ _ # ENT
SELECT PROGRAM
ENTER: _ _ PRESS #
** CODE ERROR
NOTHING CHANGED!
DIR # USED: XXXX
Please Wait . . . .
SELECT PROGRAM
ENTER: _ _ PRESS #
TALK TIME, 10-240
ENTER: _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #
Set which Relay?
(1 or 2): _