Owner manual

FUNCTION CODE LOCAL PROGRAMMING
24
CARD AND CODE
(Default setting is 0, for keypad
code or card access)
• Optional 26 BIT Wiegand Card
Reader can be used with the system.
To gain access you may use card
access, keypad access code or card
access + keypad access code.
• If no optional Wiegand Card
Reader, you only can use the 4-digit
keypad code
See Function Code 30 to program
keypad access code
See Function Code 26 and 30 to
program card reader facility code,
card number and keypad access
code
0= keypad code or card access
1= card access +
keypad access code
25 and 26
FACILITY CODE
Facility code for 26 BIT Wiegand
Card Reader or Radio Reader
(001-255)
* FUNCTION CODE 26 CAN BE
PROGRAMMED REMOTELY VIA
SOFTWARE NOT FUNCTION
CODE 25.
Step 5 Select another Function Code to program different field from the table or
press
*
to exit the programming mode.
Step 1 Log on to programming mode (see section 3.1). The display shows
Step 2 Enter Function Code 24 then press # and the display shows
Step 3 Enter 0 = KEYPAD ACCESS CODE or 1=CARD ACCESS + KEYPAD
ACCESS CODE then press # the display shows
Step 4 Select another Function Code to program different field from the table or
press
*
to exit the programming mode.
Step 1 Log on to programming mode (see section 3.1). The display shows
Step 2 Enter Function Code 26 then press # and the display shows
Step 3 Enter Card Facility Code (Facility code is provided by Pach and Company
and range from 001-255) then press #, the display shows
Step 4 Select another Function Code to program different field from the table or
press
*
to exit the programming mode.
Pach and Company Chapter 3 Page 25
AeGIS NPB9000 Series PROGRAMMING 05/01/02
SELECT PROGRAM
ENTER: _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #
CARD AND CODE
OR-(0); AND-(1):0
SELECT PROGRAM
ENTER: _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #
Fac Code (0-255)
ENTER: _ _ _ PRESS #
SELECT PROGRAM
ENTER: _ _ PRESS #