Owner manual

Technical Specifications:
AeGIS NPB9000 Series
Power Input: 12 VAC 40 VA (supplied) or 12 VDC 40VA UL Listed Transformer
Current Consumption: AeGIS 9000NCMain Lobby Control Panel: Min 700mA idle, Max 900mA operation with
optional Wiegand Card Reader and Radio Reader.
MS79xxx Main Relay Control Panel: 50 mA Idle, 680 mA Operation.
MX79xxx Expanded Relay Panel: 50 mA Idle, 680 mA Operation.
Emergency Battery: 12Vdc, 4Ahr rechargeable (not supplied)
Telephone Line: Standard voice grade RJ11 jack.
Night Light: 14V 0.080A 15,000 Average life hours.
Operating Environment: Temp. 32°F to +140°F Relative Humidity 0% to 95% non-condensing.
* Heater Pad (AHP5) is required if the ambient temperature is below 32°F.
Relay Output: Form C Dry Contact 120 VAC 10A/ 24VDC 10A/ 250VAC 7A
Memory Type: EEPROM
Tone Detection: Crystal controlled, capable of detecting short bursts 80 ms
Ringer Equivalence: 0.6B
Mounting: Surface or Semi-Flush. Indoor or Outdoor (Main Lobby) and Indoor Only (MS79xxx and MX79xxx).
Construction: 16-gauge cold rolled steel back box with brush stainless steel face plate or brass plating face plate.
16-gauge cold rolled steel box with enamel finished (MS79xxx and MX79xxx)
Shipping: 40 lbs-75 lbs.
Dimensions(HWD) : 13-1/2"x 11-1/4 x 3-7/8" (Main Lobby)
16-1/6”x 14-1/6”x 3-5/8” (MS79012-48 and MX79012-48)
23”x 12”x 3-5/8” (MS79060-120 and MX79060-120)
Specifications subject to change without prior notice
26 Bit Wiegand Card Reader (AWCR)
Power Input: 4.75 -18 VDC Regulated (Power by the AeGIS NPB9000 Series +5VDC).
Transmit Frequency: 125 Khz.
Cable Distance: 500 feet maximum.
Dimension: 5.0” x 1.6” x 0.75” (HWD)
26 Bit Wiegand Radio Reader (AWRR)
Power Input: 5.0 VDC Regulated (Power by the AeGIS NPB9000 Series +5VDC regulated) or
6.0 - 24 VDC Unregualted (not supplied).
Transmit Frequency: 318 Mhz.
Bandwith: 300 Khz minimum.
Read Range: 5 - 500 feet
Accessories and Replacement Parts:
Visit our website www.pach-co.com or call 1-888-678-7224
1.3 Unpacking the System
Standard AeGIS NPB9000 Series consists of the following items:
• AeGIS 9000NC and MS79xxx or MX79xxx.
• 2 of XMFR (Power Transformer, 12VAC 40VA).
• 7-pin terminal connector (inside the AeGIS 9000NC)
• Two 5-pin terminal connector (inside the AeGIS 9000NC and the MS79xxx).
• 2 of 3-pin terminal connector (inside AeGIS 9000NC).
• Two 6-pin terminal connector (inside the AeGIS 9000NCand the MS79xxx).
• RJ71X12 or RJ71X24.
• Two Key sets (2 keys per set)
• RJ-11 adapter (inside the AeGIS 9000NC).
• Owners Manual.
Pach and Company Chapter 1 Page 2
AeGIS NPB9000 Series GETTING STARTED 05/01/02