Datasheet

CT (ACT)
4
ds_61205_0000_en_ct: 061006J
6-(1). Electrical life test (Motor free)
Sample: ACT212, 3pcs.
Load: 5A steady, Inrush 25A, 14V DC
Brake current: 13A 14V DC,
Power window motor actual load (free condition)
Operating frequency: (ON : OFF = 0.5s : 9.5s)
Ambient temperature: Room temperature
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
M
Sample
0
2
4
6
8
10
01020
No. of operations, × 10
4
Pick-up and drop-out voltage, V
Pick-up voltage
Drop-out voltage
X
X
Max.
Max.
Min.
Min.
Contact welding: 0 time
Miscontact: 0 time
0
No. of operations, × 10
4
Contact resistance, mΩ
Max.
Min.
X
50
40
30
20
10
02010
Load current waveform
Inrush current: 25A, Steady current: 6A
Brake current: 13A
100ms
10A
6-(2). Electrical life test (Motor lock)
Sample: ACT212, 3pcs.
Load: 25A 14V DC
Switching frequency: (ON : OFF = 0.5s : 9.5s)
Ambient temperature: Room temperature
Circuit:
Change of pick-up and drop-out voltage Change of contact resistance
M
Sample
0
2
4
6
8
10
0510
No. of operations, × 10
4
Pick-up and drop-out voltage, V
Pick-up voltage
Drop-out voltage
X
X
Max.
Max.
Min.
Min.
Contact welding: 0 time
Miscontact: 0 time
0
No. of operations, × 10
4
Contact resistance, mΩ
Max.
Min.
X
50
40
30
20
10
0105
Load current waveform
100ms
5A