OTHER FUNCTIONS screen
Item Setting Notes
USER FILE Saves user files to camera memory, loads them into
camera memory or initializes them. (For details, refer
to page 80.)
LOAD, SAVE, INITIAL
This does not affect options in the SCENE FILE
screen.
Not available when PC MODE SELECT
is set to USB DEVICE and PC MODE
is set to ON.
1394 CONTROL Selects the method the camera uses for controlling
external devices connected to the DVCPRO/DV
connector. (For details, refer to page 145.)
EXT: Controls only the external device, but does not
transfer data to the camera for recording.
BOTH: Controls both the external device and the
camera, and also records.
CHAIN: When there is no more space left for recording
in the camera, recording is automatically made to the
external device.
OFF: No control
Not available in AVC-Intra mode and
DVCPRO HD native mode.
Not available during interval, one-shot
and loop recording.
1394 CMD SEL Determines how recording is stopped when the
camera controls an external device connected to the
DVCPRO/DV connector.
REC_P: Engages REC/PAUSE status.
STOP: Stops recording.
Not available in AVC-Intra mode and
DVCPRO HD native mode.
Not available during interval, one-shot
and loop recording.
ACCESS LED Determines whether or not the P2 CARD ACCESS LED
should light.
ON, OFF
ALARM Sets the alarm sound output when an alarm occurs.
HIGH, LOW, OFF
CLOCK SETTING Sets the internal calendar (date)
For details, see [Setting Date and Time of Internal
Clock] (page 26).
TIME ZONE Sets the time difference relative to Greenwich Mean
Time (GMT).
–12:00 ... 0:00 ... +13:00
For details, see [Setting Date and Time of Internal
Clock] (page 26).
This setting cannot be initialized by
performing the MENU INIT option and
the INITIAL option in USER FILE.
GL PHASE Selects the output signal whose phase is locked to
the signal input to the GENLOCK IN connector in HD
(1080i, 720P) mode. (For details, refer to page 64.)
HD SDI: The HD SDI is locked to the genlock input.
COMPOSITE: The down-converted composite signal
(VIDEO OUT or SDI OUT 480i signal) is locked to the
genlock input.
Not available when SYSTEM MODE is
set to 480-59.94i.
H PHASE Adjusts the horizontal phase when phase is locked to
the signal input to the GENLOCK IN connector.
–512 ... 0 ... +511
Hold down the JOG dial button and
turn it downwards or upwards and
maintain this position to quickly
change values.
MENU INIT Restores all setting menu values including all scene
files F1 to F6 and user files to their factory defaults.
Not available when PC MODE SELECT
is set to USB DEVICE and PC MODE
is set to ON.
____ indicates the factory setting