DC OUT Connector and External REC Start/Stop Switch Connection
The DC OUT connector on the camera can output a 1.5 A
current.
Connecting an external switch to this connector enables
REC Start and Stop control.
An LED can be connected and used as a tally lamp, which
is convenient when the camera is mounted on a crane
during recording.
DC OUT connector
1
23
4
LED
REC
Cable connector
HR10A-7P-4P(73)
Hirose Electric Co.
Max. 50 mA
Resistance
Start/Stop
1: GND
2: TALLY OUT
The AG-HPX300P has open collector output
TALLY ON:
Low impedance
TALLY OFF:
High impedance
3: REC Start/Stop switch
This pin is connected in parallel with the REC button
and the lens VTR button.
4: +12 V
NOTE:
Make sure that the total current output by DC OUT, REMOTE,
VF and LENS connectors does not exceed 2.5 A.
Be sure to check polarity before connecting an external
device as incorrect connection could lead to damage.