Datasheet

GN (AGN)
1
ds_61007_0000_en_gn: 061006J
SPECIFICATIONS
ULTRA-SMALL PACKAGE
SLIM POLARIZED RELAY
GN RELAYS (AGN)
TESTING
5.70±0.3
.224±.012
10.60±0.3
.417±.012
9.00±0.3
.354±.012
5.70±0.3
.224±.012
10.60±0.3
.417±.012
Max.10.00
.394
mm inch
FEATURES
• Compact slim body saves space
Thanks to the small surface area of 5.7
mm × 10.6 mm .224 inch × .417 inch and
low height of 9.0 mm .354 inch, the
packaging density can be increased to
allow for much smaller designs.
• Outstanding surge resistance.
Surge withstand between open contacts:
1,500 V 10×160 μs (FCC part 68)
Surge withstand between contacts and
coil: 2,500 V 2×10 μs (Telcordia)
• The use of twin crossbar contacts
ensures high contact reliability.
AgPd contact is used because of its good
sulfide resistance. Adopting low-gas
molding material. Coil assembly molding
technology which avoids generating
volatile gas from coil.
• Increased packaging density
Due to highly efficient magnetic circuit
design, leakage flux is reduced and
changes in electrical characteristics from
components being mounted close-
together are minimized. This all means a
packaging density higher than ever
before.
• Nominal operating power: 140 mW
• Outstanding vibration and shock
resistance.
Functional shock resistance:
750 m/s
2
{75G}
Destructive shock resistance:
1,000 m/s
2
{100G}
Functional vibration resistance:
10 to 55 Hz (at double amplitude of 3.3
mm .130 inch)
Destructive vibration resistance:
10 to 55 Hz (at double amplitude of 5 mm
.197 inch)
Contact
Remarks:
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as “Initial breakdown voltage” section.
*
2
Detection current: 10mA.
*
3
Nominal voltage applied to the coil, excluding contact bounce time.
*
4
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*
5
Half-wave pulse of sine wave: 6 ms; detection time: 10μs.
*
6
Half-wave pulse of sine wave: 6 ms.
*
7
Detection time: 10μs.
*
8
Refer to 6. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (p. 19, Relay Technical Information).
Characteristics
Notes:
#1 This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the
actual load.
#2 The upper limit for the ambient temperature is the maximum temperature that
can satisfy the coil temperature rise. Under the packing condition, allowable
temperature range is from –40 to +70°C –40° to +158°F.
Arrangement 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1A )
100 mΩ
Contact material
Stationary: AgPd+Au clad
Movable: AgPd
Rating
Nominal switching capacity
(resistive load)
1 A 30 V DC
0.3 A 125 V AC
Max. switching power
(resistive load)
30 W, 37.5 V A
Max. switching voltage 110 V DC, 125 V AC
Max. switching current 1 A
Min. switching capacity
(Reference value)
#1
10 μA 10 mV DC
Nominal
operating
power
Single side stable
140mW (1.5 to 12 V DC)
230mW (24 V DC)
1 coil latching
100mW (1.5 to 12 V DC)
120mW (24 V DC)
Expected
life (min.
operations)
Mechanical (at 180 cpm) 5 × 10
7
Electrical
(at 20 cpm)
1 A 30 V DC
resistive
10
5
0.3 A 125 V
AC resistive
10
5
Initial insulation resistance*
1
Min. 1,000MΩ (at 500V DC)
Initial
breakdown
voltage*
2
Between open contacts 750 Vrms for 1min.
Between contact sets 1,000 Vrms for 1min.
Between contacts and coil 1,500 Vrms for 1min.
Initial surge
voltage
Between open contacts
(10×160 μs)
1,500 V (FCC Part 68)
Between contacts and coil
(2×10 μs)
2,500 V (Telcordia)
Operate time [Set time]*
3
(at 20°C)
Max. 4 ms (Approx. 2 ms)
[Max. 4 ms (Approx. 2 ms)]
Release time (without diode)
[Reset time]*
3
(at 20°C)
Max. 4 ms (Approx. 1 ms)
[Max. 4 ms (Approx. 2 ms)]
Temperature rise*
4
(at 20°C) Max. 50°C
Shock resistance
Functional*
5
Min. 750 m/s
2
{75G]
Destructive*
6
Min. 1,000 m/s
2
{100G]
Vibration resistance
Functional*
7
10 to 55 Hz at double
amplitude of 3.3 mm
Destructive
10 to 55 Hz at double
amplitude of 5 mm
Conditions for
operation, transport
and storage*
8
(Not freezing and
condensing at low
temperature)
Ambient
temperature
#2
–40°C to 85°C
–40°F to 185°F
Humidity 5 to 85% R.H.
Unit weight Approx. 1 g .035 oz

Summary of content (4 pages)