Dial Up Adapter Model AW- Before attempting to connect, operate or adjust this product, please read these instructions completely.
FCC Note: This device complies with Part 15 of the FCC Rules. To assure continued compliance follow the attached installation instructions and do not make any unauthorized modifications. CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Menu settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Attaching the rack mounting adapters . . . . . . . . . . . . . 19 Parts and their functions . . . . . . . . . . . . . . . . . . . . . . . . . 4 Changing the position of the rear panel . . . . . . . . . . . 19 Control panel . . . . . . . . . . .
Parts and their functions $ Control panel 1 2 3 4 5 1 POWER indicator This lights when power is supplied to the main unit and the POWER switch is set to ON. 2 POWER switch This is the unit’s power switch. 3 LCD panel This displays the current statuses and menu settings. 4 Operating keys These keys are used for dialing and to perform menu settings. These keys are also used to operate the pan-tilt head system in direct mode.
Parts and their functions $ Rear panel 6 8 RS-232C CONTROL OUT TO CAMERA & PAN/TILT HEAD 9 TO MODEM INPUT TO RCB/PC DC 12V IN P5 P4 P3 P2 P1 RS-422 CONTROL OUT TO CAMERA & PAN/TILT HEAD A B P5 P4 P3 P2 > ? TO CONTROL PANEL P1 OUT PUT PAN/TILT CONTROL IN : ; 7 GND CAMERA CONTROL IN < = : PAN/TILT CONTROL IN connector This is used to connect the controller. When an AW-RP301, AW-RP501 or AW-RP505 is being used, connect it to the PAN/TILT CONTROL OUT connector.
Connections Turn off the power of all components before proceeding with the connections. Transmitting system connections Connect the control panel Coaxial cable (5C-2V) Set the control panel selector switch to B. 10Base-T cable AW-PS301 Control panel AW-DU600 RS-232C cable Modem AW-PS301 Telephone line OWhen an AW-RP301 or AW-RP501 is being used, connect the receiving pan-tilt head system to the P1 CONTROL OUT connector.
Connections Transmitting system connection procedure 1. Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. 2. Set the control panel selector switch on this adapter. Set it to A when using an AW-RP605. Set it to B when using an AW-RP301, 501, 505, or WVCB700A. 3. Connect the PAN/TILT CONTROL OUT connector on the control panel to the PAN/TILT CONTROL IN connector on this adapter using a 10 BASE-T (equivalent to UTP category 5) straight cable.
Connections Receiving system connections $ Connect the pan-tilt head system to the RS-232C CONTROL OUT connector: When an AW-PH300A is used and the connection distance is 10 m or less: Telephone line Modem AW-DU600 AW-CA50A15 AW-PS301 Convertible camera AW-PH300A AW-CA28T9 AW-PS300 When an AW-PH600 is used: Telephone line Modem AW-DU600 AW-PS301 AW-CA50D15 (component) AW-CA50A15 (composite) AW-CH600 AW-CA24U10 P-T CONTROL CAMERA CONTROL AW-PH600 G/L video (BNC cable) AW-CA16U10 Video (BNC cable)
Connections $ Connect the pan-tilt head system to the RS-422 CONTROL OUT connector: Use the RS-422 connector when the AW-PH350 is to be used as the pan-tilt head or when the connection distance between this adapter and the pan-tilt head is to exceed 10 m.
Connections When an AW-PH600 is used and the connection distance is more than 10 m: Telephone line Modem AW-DU600 AW-PS301 AW-CA50D15 (component) AW-CA50A15 (composite) AW-CH600 10 Base-T cable RS-232C/RS-422 converter AW-CA24U10 P-T CONTROL CAMERA CONTROL AW-PH600 AC adapter G/L video (BNC cable) AW-CA16U10 Video (BNC cable) COMPONENT AW-PS600 Refer to the Operating Instructions of the AW-PH600 for details on how to perform the connections for the AW-PH600.
Connections Receiving system connection procedure 1. Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. 7. Set the power switch on the modem and the pan-tilt head to ON. 2. Connect the TO MODEM connector to the RS-232C connector on the modem using the RS-232C cable provided with the modem. 8. “OK” appears on the LCD panel. 3. Connect the telephone line to the line input jack on the modem. 4. Connect the pan-tilt head to this adapter.
Connections 5. Making a call Make a call from the AW-DU600 of the transmitting system. 1. Turn on the power to all units. 2. Use the number keys on this adapter to enter the desired number. The telephone number entered appears on the top section of the LCD panel. !Telephone number entered 0123456789 1: Press Start If the wrong number is entered by mistake, press the DELETE key ( # i 0 ) to delete 1 digit at a time, starting from the number entered last.
Connections $ Direct mode 1.
Connections Connection procedure 1. Connect the pan-tilt head system to the CONTROL OUT connector on this adapter. 2. Turn on the power to this adapter and the pan-tilt head system. 3. Dial Up Adapter settings 1 Set this adapter to direct mode. Press the MENU+ key ( 2 i START ) to open the menu settings. When “Menu-1 Function” appears on the LCD panel, STOP use the ! START # keys and select Direct (direct mode). 5.
Connections 2. Control the pan-tilt head system using a control panel or PC: Coaxial cable (5C-2V) 10Base-T cable AW-PS301 AW-DU600 Control panel AW-CA50T29 Convertible camera AW-PH350 AW-PS301 10 Base-T cable AW-PS300 AW-CA50T9 PC AW-PS301 AW-DU600 AW-CA50T29 Convertible camera AW-PH350 10 Base-T cable AW-PS300 AW-RP605 cannot be used as the control panel with direct mode.
Connections Connection procedure 1. Connect the AW-PS301 AC adapter to the DC 12V IN connector on this adapter. 2. Set the control panel selector switch on this adapter to B. 3. 1 Connect the PAN/TILT CONTROL OUT connector on the control panel to the PAN/TILT CONTROL IN connector on this adapter using a 10 BASE-T (equivalent to UTP category 5) straight cable. The connection distance can be extended up to 500 meters.
Menu settings $ How to perform menu settings START STOP MENU MENU CLEAR RECALL 1 2 3 M1 M2 M3 TELE O Press the MENU+ key ( 2 i START ) and the first menu item will appear on the LCD. O Press the MENU+ key ( 2 i START ) while a menu item is displayed on the LCD and the display will move to the next item. O Press the MENU+ key ( 2 i START ) again and the last menu item will appear on the LCD.
Menu settings The following items are only displayed when this adapter is in Direct mode This setting selects which connector is to be used for the controller when this adapter is in Direct mode. Menu-4 Input RS-232C TO RCB/PC connector (PC used for control) (Initial setting:RS-232C) RS-422 PAN/TILT CONTROL IN connector (control panel used for control) This setting selects which pan-tilt head system is to be controlled by this adapter when this adapter is in Direct mode.
Attaching the rack mounting adapters To install the adapter in a rack, use the rack mounting adapters and four of the mounting screws (M4) supplied. Screw Rack mounting adapter Changing the position of the rear panel 3. Use the three screws to firmly secure the rear panel where the blank panel was removed from the bottom panel. 1. Remove the three screws from the bottom panel and remove the blank panel.
Attaching the joint angle adapter To attach the adapter to the controller, use the joint angle adapter, rack mounting adapter and mounting screws (M4 x 8) supplied.
Specifications Output connectors: RS-232C CONTROL OUT TO CAMERA & PAN/TILT HEAD D-sub, 9-pink5 (connect to pan-tilt head) RS-422 CONTROL OUT TO CAMERA & PAN/TILT HEAD RJ45k5 (connect to pan-tilt head) 10BaseT straight cable (UTP category 5), max. 1000 m I/O connector TO MODEM D-sub, 9-pin k1 (connects to analog modem) Other A/B selector switch Control panel selector switch A: AW-RP605 B: AW-RP301, AW-RP501, AW-RP505 and WVCB700A Power supply: DC 10.
PANASONIC BROADCAST & TELEVISION SYSTEMS COMPANY UNIT COMPANY OF MATSUSHITA ELECTRIC CORPORATION OF AMERICA Executive Office: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7000 EASTERN ZONE: One Panasonic Way 4E-7, Secaucus, NJ 07094 (201) 348-7621 Southeast Region: 1225 Northbrook Parkway, Ste 1-160, Suwanee, GA 30024 (770) 338-6835 Central Region: 1707 N Randall Road E1-C-1, Elgin, IL 60123 (847) 468-5200 WESTERN ZONE: 3330 Cahuenga Blvd W.