AC Adapter AW-PS300 Operating Instructions

-4-
t AC 120V Inlet [AC IN](AC 3P Inlet)
Connect the supplied AC cable.
y Option Switch Terminal (OPTION SW CONTROL
OUT) (2P Terminal Board)
A relay switch capable of controlling the contact to
short or open from a Control Panel (AW-RP301, AW-
RP305, AW-RP501, or AW-RP505). The terminal board
has a maximum capacity of 120 V, 1 A (AC/DC), and is
valid when it is connected to OPTION SW CONTROL IN
Terminal u on the pan/tilt head.
u Option Switch Control Input Terminal (OPTION SW
CONTROL IN) (1P Terminal Board)
Connect it to OP Output Terminal on the pan/tilt head
when controlling OPTION SW CONTROL OUT Terminal
AC IN
LAMP AC OUT
100V 500W
OPTION SW
CONTROL OUT
OPTION SW
CONTROL IN
LAMP
CONTROL
OP SC
DC 15V
OUT
+
FRONT PANEL
y to short or open, using a cable (to be locally pur-
chased) with a nominal cross section of 0.3 mm
2
or
more that meets the UL specifications. The maximum
allowable cable length is 30 meters.
Applicable Wire
Solid wire: ø1.02 (AWG 18)
Stranded wire: 0.75 mm
2
Usable wire range
Solid wire: ø0.64 to ø1.02
(AWG 22 to 18)
Stranded wire: 0.3 mm
2
to 0.75 mm
2
(AWG 22 to 20)
Strand diameter: ø0.18 or more
Standard bare end length 10 mm