Operating Instructions

15
Basic operations of the unit
1 Turn on the unit’s power.
Set the POWER switch to the ON position.
Power is now supplied to the unit, and the POWER
indicator lights.
p However, when [CAMERA] [POWER] AUTO
ON item have been selected and “On” is selected as
the AUTO ON item setting, power-on is automatically
instructed for the remote cameras controlled by the
[SYSTEM] CAM IP DR item.
2 Select the remote cameras.
Select the remote cameras to be controlled using the
CAMERA STATUS/SELECTION buttons.
3 Adjust the direction in which the remote
cameras are to be pointed.
Use the PAN/TILT lever to adjust the direction in which
the remote cameras are to be pointed.
4 Adjust the zoom.
Use the ZOOM button to adjust the lens zoom.
When the TELE side is pressed, the zoom is set to the
telephoto mode; when the WIDE side is pressed, it is
set to the wide-angle mode.
POWER ALARM F1 CAMERA
OSD
R/B GAIN R/B PED
SYSTEMSETUPCAMERA
SCENE/MODE
DETAIL
DELETESTORE
PAGEMENU F2 EXIT
USER2USER1
PT ACTIVEAUTOIRIS
AUTO
HILOW
PTZ/FOCUS SPEED PAN/TILTFOCUS/PUSH OAF
TELE
ZOOM
WIDE
CAMERA STATUS / SELECTION
PRESET MEMORY / MENU
GAIN/PED
F2
F1
123
AWB/ABB
4
SHUTTER
5
12345
678910
26
3
5
4
1, 7
For detailed operations, refer to the directions in the sections
below.
5 Adjust the lens iris.
Use the IRIS dial to adjust the lens iris.
p While the lens iris is being adjusted, a level meter is
displayed on the LCD panel. (What is displayed by
the level meter is an approximate value.)
------
4
------
6 Adjust the focus.
Turn the FOCUS/PUSH OAF dial, and adjust the lens
focus.
When the dial is pressed during manual focusing, the
auto focus mode is established temporarily, and the
subject is brought into focus automatically.
7 Turn off the unit’s power.
Set the POWER switch to the OFF position.
The unit’s power is turned off, and the POWER indicator
goes off.
p Even when the unit’s power is turned off, the power
of the connected remote cameras does not go off.