Datasheet

27
1
0
c
m
o
r
m
o
r
e
10 cm
or more
1
0
0
c
m
o
r
m
o
r
e
3
0
c
m
o
r
m
o
r
e
5
c
m
o
r
m
o
r
e
5 cm
or more
Piping direction
Right
Right
Rear
Right bottom
Left
Rear
Left bottom
Left
(Front side)
Attention not to bend
up drain hose
Insulation of piping connections
Carry out insulation after
checking for gas leaks and
secure with vinyl tape.
Attaching the remote control holder to
the wall
Remote control holder
fixing screws 6
Remote
control 3
Remote
control
holder 5
• This illustration is for explanation purposes only.
The indoor unit will actually face a different way.
(*) Vinly tape
AUTO
HEAT
COOL
DRY
FAN
SPEED
AIR
SWING
e
-Ion
PATROL
OFF/ON
TEMP
MODE
FAN SPEED
AIR
SWING
QUIET
TIMER
POWERFUL
ON SET
OFF
CANCEL
123
AC
SETCHECKCLOCK RESET
RC
P anasonic
INVERT ER
(Left and right
are identical)
Installation plate 1
Sleeve (*)
Bushing-Sleeve (*)
Putty (Gum Type Sealer) (*)
Bend the pipe as closely on the wall as possible,
but be careful that it doesn’t break
Vinyl tape (Wide) (*)
Apply after carrying out a drainage test.
To carry out the drainage test, remove the air
filters and pour water into the heat exchanger.
Saddle (*)
Connecting cable
4 x 1.5 mm
2
or more.
Type designation 245 IEC 57 (H05RN-F)
Additional drain hose (*)
1/4” Liquid side piping (*)
3/8” Gas side piping (*)
Installation parts you
should purchase (*)
15A
Breaker
50Hz
230V
Power supply cable:
3 x 1.5mm
2
or more.
Type designation 245 ICE
57 (H05RN-F)
12. Installation Instruction
12.1 Select the Best Location
12.1.1 Indoor Unit
There should not be any heat source or steam near the unit.
There should not be any obstacles blocking the air circulation.
A place where air circulation in the room is good.
A place where drainage can be easily done.
A place where noise prevention is taken into consideration.
Do not install the unit near the door way.
Ensure the spaces indicated by arrows from the wall, ceiling, fence or other obstacles.
Recommended installation height for indoor unit shall be at least 2.3m.
12.1.2 Outdoor Unit
If an awning is built over the unit to prevent direct sunlight or rain, be careful that heat radiation from the
condenser is not obstructed.
There should not be any animal or plant which could be affected by hot air discharged.
Keep the spaces indicated by arrows from wall, ceiling, fence or other obstrucles.
Do not place any obstrucles which may cause a short circuit of the discharged air.
If piping length is over the rated length, additional refrigerant should be added as shown in the table below:
Piping size Model
Gas Liquid
Rated Length (m) Max Elevation (m) Min Piping Length
(m)
Max Total Piping
Length (m)
Additional
Refrigerant (g/m)
CU-2E15GBE 3/8” 1/4” 15 10 3m / Indoor Unit 30 20
Note:
1. It is possible to extend the piping length of one unit to 20 meters. However, the total piping length must not
exceed 30 meters.
2. If the piping length exceeds 20 meters, refrigerant of 20g per meter must be added.
12.1.3 Indoor/Outdoor Unit Installation Diagram