13.2.7.2 Horizontal airflow
For CS-E7, 9, 12, 15GKD/GKE, the horizontal airflow direction louvers can be adjusted manually by hand.
For CS-E18GKD/GKE, automatic airflow direction can be set using remote control; the vane swings left and right
within the angles as stated below. For heating mode operation, the angle of the vane depends on the indoor
heat exchanger temperature as Figure 1 below.
Operation Mode Vane angle (°)
A 68 ~ 112
Heating, with heat exchanger temperature
B 90
Cooling and soft dry 68 ~ 112
For CS-E18GKD/GKE, manual vertical airflow direction can be set using remote control; the angles of the vane
are as stated below and the positions of the vane are as Figure 2 above.
Pattern 1 2 3 4 5
Airflow direction
patterns at remote
control
Vane angle (°) 90 68 79 101 112
13.2.8 Quiet operation (Cooling mode/Cooling area of Dry mode)
Purpose
To provide quiet cooling operation compare to normal operation.
Control condition
Quiet operation start condition
1. When “quiet” button at remote control is pressed. Quiet LED illuminates.
Quiet operation stop condition
1. When one of the following conditions is satisfied, quiet operation stops:
o Powerful button is pressed.
o Stop by OFF/ON switch.
o Timer “off” activates.
o Quiet button is pressed again.
2. When quiet operation is stopped, operation is shifted to normal operation with previous setting.
3. When fan speed is changed, quiet operation is shifted to quiet operation of the new fan speed.
4. When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.
5. During quiet operation, if timer “on” activates, quiet operation maintains.
6. After off, when on back, quiet operation is not memorized.
Control content
Fan speed is changed from normal setting to quiet setting of respective fan speed. This is to reduce sound of Hi,
Me, Lo for 3dB.
Fan speed for quiet operation is -1 step from setting fan speed.