13.2.10 Powerful mode operation
When the powerful mode is selected, the internal setting temperature will shift to achieve the setting temperature
quickly.
Cooling operation
Internal setting
temperature
20min
-2.0°C
When powerful button is
pressed
Soft dry operation
Internal setting
temperature
20min
-1.0°C
When powerful button is
pressed
Heating
Internal setting
temperature
20min
+3.5°C
When powerful button is
pressed
ON timer control
ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time.
This is to provide a comfortable environment when reaching the set ON timer.
60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds
to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation
starting time.
From the above judgment, the decided operation will start operate earlier than the set time as shown below.
13.2.11 OFF timer control
OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
Indoor intake air
temperature (°C)
Indoor intake air
temperature (°C)
15 min 25 min
30 15
10 min 30 min
25 5
5 min
35 min
30 35 (°C)
Outdoor air
temperature (°C)
0 5 (°C)
Outdoor air
temperature (°C)
Cooling/ Soft Dry Heating
13.2.12 Auto restart control
When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly. After power supply resumes.
This type of control is not applicable during ON/OFF timer setting.