13.2.10 Powerful mode operation
When the powerful mode is selected, the internal setting temperature will shift to achieve the setting temperature
quickly.
• Cooling operation
Internal setting
temperature
20min
-2.0°C
When powerful button is
pressed
• Soft dry operation
Internal setting
temperature
20min
-1.0°C
When powerful button is
pressed
• Heating
Internal setting
temperature
20min
+3.5°C
When powerful button is
pressed
ON timer control
• ON timer can be set using remote control, the unit with timer set will start operate earlier than the setting time.
This is to provide a comfortable environment when reaching the set ON timer.
• 60 minutes before the set time, indoor (at fan speed of Lo-) and outdoor fan motor start operate for 30 seconds
to determine the indoor intake air temperature and outdoor air temperature in order to judge the operation
starting time.
• From the above judgment, the decided operation will start operate earlier than the set time as shown below.
13.2.11 OFF timer control
• OFF timer can be set using remote control, the unit with timer set will stop operate at set time.
Indoor intake air
temperature (°C)
Indoor intake air
temperature (°C)
15 min 25 min
30 15
10 min 30 min
25 5
5 min
35 min
30 35 (°C)
Outdoor air
temperature (°C)
0 5 (°C)
Outdoor air
temperature (°C)
Cooling/ Soft Dry Heating
13.2.12 Auto restart control
• When the power supply is cut off during the operation of air conditioner, the compressor will re-operate within
three to four minutes (there are 10 patterns between 2 minutes 58 seconds and 3 minutes 52 seconds to be
selected randomly. After power supply resumes.
• This type of control is not applicable during ON/OFF timer setting.