Operating instructions

38
Indoor Unit
Outdoor Unit
Test conditions
1. Cooling: Indoor Dry Bulb Temp. (°C) 27 Outdoor Dry Bulb Temp. (°C) 35
Wet Bulb Temp. (°C) 19 Wet Bulb Temp. (°C) 24
Heating: Indoor Dry Bulb Temp. (°C) 20 Outdoor Dry Bulb Temp. (°C) 7
Wet Bulb Temp. (°C) 12 (MAX) Wet Bulb Temp. (°C) 6
2. Standard piping length: 7.5m (Includes Indoor Unit piping length).
Model
CS-PW9GKX
CU-PW9GKX
CS-PW12GKX
CU-PW12GKX
COOL HEAT COOL HEAT
Single, 230V, 50Hz Single, 230V, 50Hz
Power/Current
[kW] 0.825 0.785 1.055 1.050
[A] 3.90 3.70 5.00 4.90
Refrigerant
[k
g
]
R410A
0.800
R410A
0.980
Cooling Capacity
[kW] 2.650 3.400
Heating Capacity
[kW] 2.850 3.800
Noise Level
JIS C 9612
[<70 dB(A)]
[dB(A)]
39 39 39 39
Conditions
1mDistance
Max.cooling/
heating
operation
48 49 49 50
Sound power
level
[dB(A)]
50 50 50 50
61 62 62 63
Air Circulation
[m
3
/min.] 10.3 10.3 9.0 9.2
Product Weight
[k
g
]
7.5 9.0
27 30
Dimensions(LxWxH)
[mm]
770×205×250 799×183×280
650×230×530 780×289×540
kg
produCt SpeCifiCation produCt SpeCifiCation
F566809_EN1.indd 38 2009-1-16 18:05:45