Datasheet

15
I/O CIRCUIT AND WIRING DIAGRAMS
I/O circuit diagram
+
12 to 24 V DC
±10 %
D
Tr
ZD
ZD
100 mA max.
(Brown / 1) +V
(Black / 4)
Output (Note 1)
Color code / Connector pin No. of the connector type
(Blue / 3) 0 V
*1
Load
D
User’s circuitInternal circuit
(Pink / 2) Sensing mode
selection input (Note 2, 3)
Sensor circuit
Notes: 1) The emitter of the thru-beam type sensor does not
incorporate the output.
2) Sensing mode selection input is incorporated only for the
CX-44 adjustable range refl ective type. When using the
CX-44, be sure to wire the sensing mode selection input
(pink / 2) as mentioned *
1
. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector
type of CX-44, its color is white.
*1
Sensing mode selection input
BGS function: Connect to 0 V
FGS function: Connect to +V
Symbols ... D : Reverse supply polarity protection diode
Z
D
: Surge absorption zener diode
Tr : NPN output transistor
NPN output type
Wiring diagram
+
*1
Load
Brown
Black (Note 1)
Blue
Pink (Note 2, 3)
12 to 24 V DC
±10 %
Notes: 1)
The emitter of the thru-beam type sensor does not incorporate the black wire.
2)
The pink wire is incorporated only for the CX-44 adjustable
range refl ective type. When using the CX-44, be sure to wire
the pink wire as mentioned *
1
. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector
type of CX-44, its color is white.
*1
Sensing mode selection input
BGS function: Connect to 0 V
FGS function: Connect to +V
Connector pin position
M8 plug-in connector type
M12 pigtailed type
2
Sensing mode
selection input
(Note 2)
4
Output
(Note 1)
1
+V
3
0 V
2
Not
connected
1
+V
3
0 V
4
Output (Note 1)
Notes: 1)
The emitter of the thru-beam type sensor does not incorporate the output.
2) Sensing mode selection input is incorporated only for the
CX-44 adjustable range refl ective type. When using the
CX-44, be sure to wire the sensing mode selection input
(pink / 2). Unstable operation may occur.
PNP output type
I/O circuit diagram
Tr
ZD
ZD
100 mA max.
User’s circuitInternal circuit
Load
(Brown / 1)
+V
(Black / 4) Output (Note 1)
Color code / Connector pin No. of the connector type
(Blue / 3) 0 V
D
D
12 to 24 V DC
±10 %
*1
+
(Pink / 2) Sensing mode
selection input (Note 2, 3)
Sensor circuit
Notes: 1) The emitter of the thru-beam type sensor does not
incorporate the output.
2) Sensing mode selection input is incorporated only for the
CX-44-P adjustable range refl ective type. When using the
CX-44-P, be sure to wire the sensing mode selection input
(pink / 2) as mentioned *
1
. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector
type of CX-44-P, its color is white.
*1
Sensing mode selection input
BGS function: Connect to 0 V
FGS function: Connect to +V
Symbols ... D : Reverse supply polarity protection diode
Z
D
: Surge absorption zener diode
Tr : PNP output transistor
Wiring diagram
+
*1
Load
Brown
Black (Note 1)
Blue
Pink (Note 2, 3)
12 to 24 V DC
±10 %
Notes: 1)
The emitter of the thru-beam type sensor does not incorporate the black wire.
2)
The pink wire is incorporated only for the CX-44-P adjustable
range refl ective type. When using the CX-44-P, be sure to wire
the pink wire as mentioned *
1
. Unstable operation may occur.
3) When the mating cable is connected to the plug-in connector
type of CX-44-P, its color is white.
*1
Sensing mode selection input
BGS function: Connect to 0 V
FGS function: Connect to +V
Connector pin position
2
Sensing mode
selection input
(Note 2)
4
Output (Note 1)
1
+V
3
0 V
2
Not
connected
1
+V
3
0 V
4
Output (Note 1)
M8 plug-in connector type
M12 pigtailed type
Notes: 1)
The emitter of the thru-beam type sensor does not incorporate the output.
2) Sensing mode selection input is incorporated only for the
CX-44-P adjustable range refl ective type. When using the
CX-44-P, be sure to wire the sensing mode selection input
(pink / 2). Unstable operation may occur.
18/07/2011