User manual

2
The sensor mounting bracket (MS-DP1-1) is available as an option.
When mounting the sensor onto the sensor mounting bracket, etc., the
tightening torque should be 0.5N·m or less.
The panel mounting bracket MS-DP1-2 (optional) and MS-DP1-4
(optional), as well as the front cover MS-DP1-3 (optional) and DPX-04
(optional) are also available.
The type of the front cover differs depending on the mounting bracket.
Use MS-DP1-3 for MS-DP1-2, and DPX-04 for MS-DP1-4.
To mount the panel mounting bracket, refer to the Instruction Manual
enclosed with MS-DP1-2 or MS-DP1-4.
Connection method
Attach the female connector of cable
CN-14A-
to the 4-pin male connector.
Disconnection method
While pressing the release lever, pull out
the connector.
Pin assignment, 4-pin male connector
Notes:
When using the analog voltage output, pay careful attention to the
connected device’s input impedance.
If the cable is extended, the cable resistance will cause the voltage to
drop.
NPN output type
Standard type
Multifunction type
PNP output type
Standard type
Multifunction type
The EASY mode, hysteresis mode or window comparator mode can be
selected as the output mode for comparative output 1 and, for the standard
type DP-100, comparative output 2.
For details, see page 5, section 10, MENU SETTING MODE.
Easy mode
The comparative output is turned ON or OFF (depending on the N.O./N.C.
setting) when the threshold is reached. The tolerance of the threshold is
specified by the hysteresis setting. For details, see page 6, section 11, PRO
MODE.
4 MOUNTING
No. Part Description
1 M3 (length 6mm) screws
with washers
Accessory with MS-DP1-1
2 Sensor mounting bracket
(MS-DP1-1)
Optional
5 WIRING
Pin no. Terminal name
1 +V
2 Comparative output 1
3 Standard type: Comparative
output 2
Multifunction type: Analog
voltage output or external input
4 0V
6 I/O CIRCUIT DIAGRAMS
1
2
CN-14A-Cغ
<Recommended product>
Contact: SPHD-001T-P0.5
Housing: PAP-04V-S
[JST Mfg. Co., Ltd.]
Release lever
C
a
bl
e w
ith
f
ema
l
e
connector
Ԙԙ Ԛԛ
7 OUTPUT MODE AND OUTPUT OPERATION
Notes: Hysteresis can be fixed in 8 levels.
For details, see page 6, section 11, PRO MODE.
P-1 is displayed for comparative output 1 and P-2 for
comparative output 2 on the sub-display.
+
_
User’s circuitInternal circuit
12 to 24V DC
±10%
(Black)
Comparative output 1
Main circuit
(White) Comparative output 2
(Blue) 0V
100mA max.
100mA max.
Load
Load
(Brown) +V
Color code of cable with connector
+
_
±10%
5V
1kǡ
Main circuit
Users' circuitInternal circuit
(Black) Comparative output 1
(Blue) 0V
100mA max.
Load
(Brown) +V
Color code of cable with connector
12 to 24V DC
(White)
Analog voltage output
or external input
+
_
±10%
100mA max.
Main circuit
User’s circuitInternal circuit
(Black) Comparative output 1
(White) Comparative output 2
(Blue) 0V
100mA max.
Load
Load
(Brown) +V
Color code of cable with connector
12 to 24V DC
+
_
±10%
1kǡ
12 to 24V D
C
Main circuit
(Black) Comparative output 1
User’s circuitInternal circuit
(Blue) 0V
100mA max.
Load
(Brown) +V
Color code of cable with connector
(White)
Analog voltage output
or external input
P
0
H (Hysteresis)
ON
OFF
Pressure
Comparative
output