Datasheet

DSP
3
ds_61A05_en_dsp: 070313D
2. Specifications
Notes:
*1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3 Refer to “6. Usage, Storage and Transport Conditions“ in AMBIENT ENVIRONMENT section in Relay Technical Information.
REFERENCE DATA
Characteristics Item Specifications
Contact
Arrangement 1 Form A 1 Form A 1 Form B 2 Form A
Initial contact resistance, max. Max. 30 m (By voltage drop 6 V DC 1A)
Contact material Au-flashed AgSnO
2 type
Rating
Nominal switching capacity (resistive load) 8 A 250 V AC, 5A 30V DC 5 A 250 V AC, 5 A 30 V DC
Max. switching power (resistive load) 2,000 VA, 150 W 1,250 VA, 150 W
Max. switching voltage 250 V AC, 125 V DC
Max. switching current 8 A AC, 5 A DC 5 A AC, DC
Nominal operating power Single side stable, 2 coil latching: 300 mW. 1 coil latching: 150mW
Min. switching capacity (Reference value)*
1
10m A 5 V DC
Electrical
characteristics
Insulation resistance (Initial)
Min. 1,000M (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
Breakdown voltage
(Initial)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA.)
Between contact sets 2,000 Vrms (1 Form A 1 Form B, 2 Form A) (Detection current: 10mA.)
Between contact and coil 3,000 Vrms for 1min. (Detection current: 10mA.)
Surge breakdown
voltage*
2
between contacts and coil 5,000 V
Temperature rise (at 65C 149F) Max. 55C Max. 40C Max. 55C
Operate time [Set time] (at 20C 68F) Max. 10 ms [10 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20C 68F)
Max. 5 ms [10 ms] (Nominal voltage applied to the coil, excluding contact bounce time.)
(without diode)
Mechanical
characteristics
Shock resistance
Functional Min. 196 m/s
2
(Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Destructive Min. 980 m/s
2
(Half-wave pulse of sine wave: 6 ms.)
Vibration resistance
Functional 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10s.)
Destructive 10 to 55 Hz at double amplitude of 3.5 mm
Expected life
Mechanical Min. 510
7
(at 180 times/min.)
Electrical Min. 10
5
(resistive load)
Conditions
Conditions for operation, transport and storage*
3
(Not freezing and condensing at low temperature)
Ambient temperature:
–40C to +60C
–40F to +140F
Ambient temperature:
–40C to +65C
–40F to +149F
Ambient temperature:
–40C to +60C
–40F to +140F
Solder heating
250C 482F (10s), 300C 572F (5s), 350C 662F (3s)
(Soldering depth: 2/3 terminal pitch)
Max. operating speed 3 cps
Unit weight Approx. 4.5 g .16 oz
1. Max. switching capacity 2.-(1) Life curve (1 Form A 1 Form B) 2.-(2) Life curve (1 Form A 1 Form B)
10
0.1
100 1000
Contact voltage, V
Contact current, V
1
10
DC resistive
load (1a)
DC resistive load
(1a1b,2a)
AC resistive
load (1a)
AC resistive
load
(1a1b,2a)
100
10
012 43765
Switching capacity, A
No. of operations, ×10
4
265 V-130 V AC cosϕ = 1
265 V-130 V AC
cosϕ = 0.4
100
50
10
0.5 1 105
Switching capacity, A
No. of operations, ×10
4
30 V DC L/R = 7 ms
30 V DC resistive