Datasheet

DSP
6
ds_61A05_en_dsp: 070313D
SAFETY STANDARDS
* Remarks: The standard certified for may differ depending on where the product was manufactured.
NOTES
For Cautions for Use, see Relay Technical Information.
Item
UL/C-UL (Recognized) CSA (Certified) TÜV (Certified)
File No. Contact rating File No. Contact rating File No. Rating
1 Form A
E43028 8A 250V AC
1
/6HP 125, 250V AC
5A 30V DC
LR26550
etc.
8A 250V AC
1
/6HP 125, 250V AC
5A 30V DC
B 02 10
13461 238
8A 250V AC (cos=1.0)
5A 250V AC (cos=0.4)
5A 30V DC
1 Form A
1 Form B
E43028 5A 250V AC
1
/6HP 125, 250V AC
5A 30V DC
LR26550
etc.
5A 250V AC
1
/6HP 125, 250V AC
5A 30V DC
B 02 10
13461 238
5A 250V AC (cos=1.0)
3A 250V AC (cos=0.4)
5A 30V DC
2 Form A
E43028 5A 250V AC
1
/10HP 125, 250V AC
5A 30V DC
LR26550
etc.
5A 250V AC
1
/10HP 125, 250V AC
5A 30V DC
B 02 10
13461 238
5A 250V AC (cos=1.0)
3A 250V AC (cos=0.4)
5A 30V DC
3. 2 Form A type
CAD Data
External dimensions
Single side stable 2 coil latching
General tolerance: 0.3 .012
PC board pattern (Bottom view)
0.8
0.8
0.3
10.0
10.5
3.5
1.0
20.2
7.62
7.2
1.21
10.16
0.8
0.8
0.3
10.0
10.5
3.5
1.0
1.0
20.2
7.62 7.62
7.2
1.21
2.54
0.3
11.0
7.62
.031 .031
.100
.031
.012
.394
.413
.138
.039
.795
.300
.283
.048
.400
.031
.012
.394
.413
.138
.039
.039
.795
.300 .300
.283
.048
.012
.433
.300
Single side stable 2 coil latching
Tolerance: 0.1 .004
Schematic (Bottom view)
6-1.2 dia.
2.54×3
2.54×3
2.54×4
6-.047 dia.
.100×3
.100×4
.100×3
8-1.2 dia.
2.54×3 2.54×3
2.54×3
2.54
8-.047 dia.
.100×3
.100×3 .100×3 .100
Single side stable
(Deenergized condition)
2 coil latching
(Reset condition)
8 1
+
-
16
5
912
1
+
-
16
2
+
-
15
85
912
1. Soldering should be done under the
following conditions:
250C 482F within 10 s
300C 572F within 5 s
350C 662F within 3 s
2. Cleaning
For automatic cleaning, the boiling
method is recommended. Avoid
ultrasonic cleaning which subjects the
relays to high frequency vibrations, which
may cause the contacts to stick.
It is recommended that a fluorinated
hydrocarbon or other alcoholic solvents
be used.
3. External magnetic field
Since DY relays are highly sensitive
polarized relays, their characteristics will
be affected by a strong external magnetic
field. Avoid using the relay under that
condition.
4. Coil operating power
Pure DC current should be applied to the
coil. The wave form should be
rectangular. If it includes ripple, the ripple
factor should be less than 5%.
However, check it with the actual circuit
since the characteristics may be slightly
different.
5. When using, please be aware that
the a contact and b contact sides of 1
Form A and 1 Form B types may go on
simultaneously at operate time and
release time.