Manual

-
11
-
Configuring the torque clutch setting
(1)
(2)
Display
Battery indication lamp
1. Press the and buttons to select the
clutch setting that is appropriate for the
work being performed.
328
1F30 229
As the button
is pressed
As the button
is pressed
“F” indicates that the torque control func-
tion is off.
You can select from 30 torque clutch
settings (1 to 30).
Use figures from the Tightening Torque
Chart to guide your selection of torque
clutch setting. (See the following tighten-
ing torque chart)
2.
Press the OK button to accept the select-
ed torque clutch setting.
The control panel will stop flashing and
light up.
CAUTION:
You must press the OK button in order
for the selected setting to take effect.
Be sure to verify the new value after
changing the setting. (See page 12.)
Tightening Torque Chart (for Reference
Use)
The values illustrated on this chart were mea-
sured under the conditions described below
and are provided for reference purposes.
Actual tightening torque varies with ambient
conditions (the particular bolt being tightened,
hardware being used, method of holding the
bolt in place, etc.).
0
10
20
30
40
50
60
EYFLA1 (M6)
EYFLA2 (M6)
EYFLA1 (M8)
EYFLA2 (M8)
EYFLA3 (M8)
EYFLA3 (M10)
N • m
1 2 3 4 5 6 7 8 9 101112131415161718192021222324252627282930
Measurement conditions
Temperature: Room temperature (20°C/68°F)
Using the Interval Set
The interval set operates to prevent the tool
from operating after it automatically stops as
a result of the torque control function, even if
the switch is engaged.
1.
Set the tool to configuration mode.
(See page 10.)
2. Press the interval set button.
The control panel will begin flashing.
Display: The number 0 ashes on and off.
Battery indication lamp: The middle bar
of the battery ashes on and off.