Dimensions Guide

Specification Submittal Data / Panasonic Ventilation Fan
Description
Ventilating fan shall be low noise ceiling mount type
rated for continuous run. Fan shall be ENERGY
STAR rated and certified by the Home Ventilating
Institute (HVI). Fan shall also be evaluated by
Underwriters Laboratories and conform to both UL
and cUL safety standards.
Motor/Blower:
• Four–pole fully enclosed condenser motor rated
for continuous run.
• Power rating shall be 120 volts and 60 Hz.
• Fan shall be UL listed for tub/shower enclosure
when used with a GFCI protected circuit and used
in insulated ceiling (TYPE I.C.).
• Motor equipped with thermal–cutoff fuse.
• Removable with permanently lubricated plug–in
motor.
Housing:
• Rust proof paint, galvanized steel body.
• 6" diameter duct adapter.
• Built in backdraft damper.
• Built-in metal ange provides blocking for
penetrations through drywall as an Air Barrier,
and assists with the decrease in leakage in the
Building Envelope during blower door testing.
• Expandable extension bracket up to 26".
• Double hanger bar system allowing for ideal
positioning.
FV-40VQ4
Panasonic Eco Products Division
Eco Products Division Two Riverfront Plaza
Newark, NJ 07102
us.panasonic.com/ventfans
Specifications: WhisperCeiling FV-40VQ4
6" Duct
Static Pressure in inches w.g. 0.1 0.25
Air Volume (CFM) 390 356
Noise (sones) 3.0 3.0
Power Consumption (watts) 111.4 109.6
Energy Efciency (CFM/Watt) 3.5 3.3
Speed (RPM) 793 874
Current (amps) 0.99 0.98
ENERGY STAR YES
For complete Installation Instructions visit us.panasonic.com/ventfans
Model Quantity Comments Project:
Location:
Architect:
Engineer:
Contractor:
Submitted by:
Date:
FV-40VQ4
6" duct
Grille:
• Attractive design using PP material.
• Attaches directly to housing with torsion
springs.
Warranty:
• ALL Parts: 3 years from original purchase date.
Architectural Specifications:
Ventilating fan shall be ceiling mount, ENERGY
STAR rated type, with no less than 390 CFM and
no more than 3.0 sones as certied by the Home
Ventilating Institute (HVI) at .1 wg and no less
than 356 CFM and no more than 3.0 sones at
.25 wg. Power consumption shall be no greater
than 111.4 Watts at .1 wg and 109.6 Watts at
.25 wg. Energy efciency shall be no less than
3.5 CFM/Watt at .1 wg and 3.3 CFM/Watt at
.25 wg. The motor shall be fully enclosed, four
pole condenser types engineered to operate
continuously. Power rating shall be 120v/60Hz.
Duct diameter shall be no less than 6". Fan shall
be UL and cUL listed for tub/shower enclosure
when used with a GFCI protected circuit. Fan can
be used to comply with ASHRAE 62.2, LEED,
EarthCraft, California Title-24, and WA Ventilation
Code.
0.00
0.20
0.40
0.60
0.80
1.00
1.20
1.40
1.60
0 100 200 300 400
Static Pressure(inch w.g.)
Airflow(CFM)
FV-40VQ4
20 Feet
40 Feet
60 Feet
80 Feet
100 Feet
6" Duct
7" Duct
Performance Curve