Datasheet

FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC CONTROL
DEVICES
LASER
MARKERS
Selection
Guide
Amplifier
Built-in
GXL
GX-F/H
GL
GX-U / GX-FU /
GX-N
GX
GA-311 / GH
Other
Products
Amplifier-
separated
649
INDUCTIVE
PROXIMITY
SENSORS
GX-F
/
/H
Ampli er
Built-in
Related Information
Rectangular-shaped Inductive Proximity Sensor
Ampli er Built-in
GX-F/H SERIES
Industry No. 1* in stable sensing
Oil resistant
Can be installed with ample space
This sensor has the longest stable sensing range among the same level of rectangular inductive proximity sensors in
the industry. It is easy to install the sensor.
Conforming to
EMC Directive
PNP output
type available
Different freq.
type available
Variation at the maximum operation distance is within ±8 %
Temperature characteristics vary within ±8 %
Thorough adjustment and control of sensing sensitivity
greatly reduces individual sensor differences and
variations.
The work of adjusting sensor positions when using
multiple sensors and when sensors have been replaced
is much easier.
* Not including temperature characteristics.
GX-□12 has a variation of 0.64 mm 0.025 in or less for a maximum operation distance of 4 mm 0.158 in
0.4 mm 0.016 in or less
60%
60%
less
less
Standard
sensing object
Standard
sensing
object
Operation distance variation: 0.4 mm 0.016 in or less*
Operation distance variation: 1.0 mm 0.039 in or less
Maximum operation distance: 2.5 mm 0.098 in ± 8 %
(2.3 to 2.7 mm 0.091 to 0.106 in)
Maximum operation distance: 2.5 mm 0.098 in ± 20 %
(2.0 to 3.0 mm 0.079 to 0.118 in)
For the
GX-8
Previous
model
1.0 mm 0.039 in or less
Components such as the sensor coil and core and
product design have been totally revised to provide
excellent temperature characteristics.
Stable sensing can be obtained regardless of the time of
day or the yearly season.
Rate of variation in sensing range [%]
0
32
–10
14
–20
–4
–2.0
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
10
50
20
68
Ambient temperature [°C °F]
* Typical
30
86
40
104
50
122
60
140
70
158
GX-F/H series
Previous models
Previous models:
within %
)(
+15
–10
23 °C
23 °C
73 °F
73 °F
23 °C
73 °F
Sensing range within temperatures
of –25 to +70 °C
(–13 to +158 °F) are within
±8 % of the range at +23 °C (+73 °F)
Stable sensing range
2.1 to 0 mm
0.083 to 0 in
1.8 to 0 mm
0.071 to 0 in
2.5 mm
0.098 in
2.5 mm
0.098 in
GX-8: 2.1 mm 0.083 in
(Maximum operation distance: 2.5 mm 0.098 in)
GX-□8
Stable sensing range
3.3 to 0 mm
0.130 to 0 in
3.0 to 0 mm
0.118 to 0 in
4.0 mm
0.157 in
4.0 mm
0.157 in
GX-12: 3.3 mm 0.130 in
(Maximum operation distance: 4.0 mm 0.157 in)
Previous
model
GX-□12
Previous
model
General terms and conditions ............. P.1 Sensor selection guide .....P.11~ / P.647~
Glossary of terms........................ P.1009 ~ General precautions ................... P.1012 ~
http://www.sunx.com
SUNX website
* Based on research conducted by SUNX as of August 2007
among equivalent rectangular inductive sensors.