Datasheet

DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from the SUNX website: http://www.sunx.com
SPECIFICATIONS
No.LCE-GX6-5 February, 2009
Printed on 100% recycled paper PRINTED IN JAPAN
2431-1 Ushiyama-cho, Kasugai-shi, Aichi,
486-0901, Japan
Phone: +81-568-33-7211
FAX: +81-568-33-2631
SUNX Limited
Phone: +81-568-33-7861
FAX: +81-568-33-8591
Overseas Sales Division
http://www.sunx.com
All information is subject to change without prior notice.
OPTIONS
I/O CIRCUIT DIAGRAM
GX-F6
Sensor
MS-GX6-1
Sensor mounting bracket (Optional)
MS-GL6-1
Sensor mounting bracket (Optional)
MS-GL6-2
Sensor mounting bracket (Optional)
GX-F6 GX-H6
NPN output type
GX-F6-P  GX-H6-P
PNP output type
GX-H6
Sensor
2.5
0.098
25
0.984
6
0.236
11.5
0.453
Operation indicator
(Orange)
ø3 ø0.118 cable,
1 m 3.281 ft long
Sensing direction
0.5
0.020
6
0.236
6
0.236
3
0.118
0.5
0.020
ø2.4 ø0.094 hole,
3 0.118 or more deep
22.2
0.874
3.55
0.140
t 0.4
t 0.016
6.8
0.268
6.4
0.252
2.3
0.091
25.75
1.014
25.35
0.998
ø3.1
ø0.122
22
0.866
M3 × 0.5 0.020 tapped hole,
8 0.315 or more deep
2
0.079
( )
10
0.394
2.2
0.087
6
0.236
M3 × 0.5 0.020 tapped hole
(or ø3.4 ø0.134 hole)
3.2 × 3.8 0.126 × 0.150 oblong hole
ø2.4
ø0.094
hole
6
0.236
5.3
0.209
1.5
0.059
5.6
0.220
13.2 0.520
(Note)
5.5
0.217
t 0.4
t 0.160
3.
2
0.12
6
Type NPN output PNP output
Front sensing
GX-F6A(I) GX-F6B(I) GX-F6A(I)-P GX-F6B(I)-P
Top sensing
GX-H6A(I) GX-H6B(I) GX-H6A(I)-P GX-H6B(I)-P
Max. operation distance (Note 3)
1.6 mm 0.063 in ±8 %
Stable sensing range (Note 3)
0 to 1.3 mm 0 to 0.051 in
Standard sensing object
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
Hysteresis 20 % or less of operation distance (with standard sensing object)
Repeatability
Along sensing axis, perpendicular to sensing axis: 0.04 mm 0.0016 in or less
Supply voltage 12 to 24 V DC
+10
-
15
% Ripple P-P 10 % or less
Current consumption
15 mA or less
Output
NPN open-collector transistor
• Maximum sink current: 100 mA
Applied voltage: 30 V DC or less (between output and 0 V)
Residual voltage: 1 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
PNP open-collector transistor
Maximum source current: 100 mA
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 1 V or less (at 100 mA source current)
0.4 V or less (at 16 mA source current)
Output operation
Normally open Normally closed Normally open Normally closed
Max. response frequency
400 Hz
Operation indicator
Orange LED (lights up when the output is ON)
Protection IP68 (IEC), IP68g (JEM) (Note 4, 5)
Ambient temperature
-25 to +70 °C -13 to +158 °F, Storage: -40 to +85 °C -40 to +185 °F
Ambient humidity 45 to 85 % RH, Storage: 35 to 95 % RH
Sensing range
variation
Temperature characteristics
Over ambient temperature range –25 to +70 °C -13 to +158 °F: Within ±8 % of sensing range at +23 °C +73.4 °F.
Voltage characteristics
Within ±2 % for
+10
-
15
% uctuation of the supply voltage
Material Enclosure: PBT, Indicator part: Polyester
Cable
0.15 mm
2
3-core oil, heat and cold resistant cabtyre cable, 1 m 3.281 ft long
Net weight 15 g approx.
Notes: 1)
Where measurement conditions have not been specied precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) “I” in the model No. indicates a different frequency type.
3)
The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if
there is an ambient temperature drift and/or supply voltage uctuation.
4) SUNX’s IP68 test method
1
Immerse at 0 m below 0 °C +32 °F water surface and leave for 30 min. Then, immerse at 0 m
below +70 °C +158 °F water surface and leave for 30 min.
2
Regard the heat shock test in
1
as one cycle and perform 20 cycles.
3
Leave in water at a depth of 1 m 3.281 ft in water for 500 hours.
4
After tests
1
to
3
, insulation resistance, voltage withstandability, current consumption, and
sensing range must meet the standard values.
5)
If using the sensor in an environment where cutting oil droplets splatter, the sensor may be deteriorated due to added substances in the oil.
Designation Model No. Description
Sensor
mounting
bracket
MS-GX6-1
Recommended sensor mounting bracket. Sensors
can be mounted closely together for space-saving.
MS-GL6-1 
Sensor mounting brackets for GL-6 can be
used. Interchange is possible.
MS-GL6-2 
MS-GX6-1 MS-GL6-2MS-GL6-1
Note: 20 mm 0.787 in with the sensor tted.
Note: 13.4 mm 0.528 in with the sensor tted.
Mounting hole dimensions
Mounting hole dimensions
24.5
0.965
0.5
0.020
6
0.236
11
0.433
Operation indicator (Orange)
ø3 ø0.118 cable,
1 m 3.281 ft long
Sensing direction
0.5
0.020
3
0.118
6
0.236
6
0.236
2.6
0.102
Item
Model No.
(Note 2)
Sensor circuit
Color code
(Brown) +V
(Black) Output
(Blue) 0 V
12 to 24 V DC
Load
Internal circuit Users’ circuit
Sensor circuit
Color code
(Brown) +V
(Black) Output
(Blue) 0 V
12 to 24 V DC
Load
Internal circuit Users’ circuit
Mounting hole dimensions
100 mA max.
100 mA max.