Operation Manual
53
VQT3Y11
≥ To return to auto setting, select or press the iA/MANUAL button.
∫ To set the White Balance manually
1Press 2/1 to select , and fill the screen
with a white subject.
2Press 3 to set.
≥ When the display stops flashing and then lights
constantly, the setting is complete.
≥ If the display continues flashing, the White
Balance cannot be set. In this case, use other White
Balance Modes.
≥ If you turn on the unit with the lens cover closed, the Auto White Balance will not be
performed correctly. Always open the lens cover before turning on the unit.
≥ When the display flashes, the Manual White Balance previously adjusted is stored.
Whenever recording conditions change, re-set the White Balance.
≥ When setting both the White Balance and the iris/gain, set the White Balance first.
≥ is not displayed on the screen when is being set.
Icon Mode/Recording conditions
Auto White Balance adjustment
Sunny mode: Outdoors under a clear sky
Cloudy mode: Outdoors under cloudy sky
Indoor mode 1: Incandescent light, video lights like in the studio, etc.
Indoor mode 2: Colour fluorescent lamps, sodium lamps in gymnasiums etc.
Manual adjustment mode:
≥ Mercury-vapor lamps, sodium lamps, some fluorescent lights
≥ Lights used for wedding receptions at hotels, stage spotlights in theaters
≥ Sunrise, sunset, etc.
AWB
AWB
BACKBACKBACK
AWB
AWB
HC-V100&V100MEB_VQT3Y11_mst.book 53 ページ 2012年1月8日 日曜日 午後2時18分