User manual

Required items for connection
LAN cable
Either straight cable or crossing cable can be used.
(MDI/MDI-X Automatic crossover function)
Settings for Ethernet connection
Follow the procedure below to communicate with the Ethernet connection.
1. Connect the GT to a PC with an Ethernet cable.
2. Specify the settings such as IP address for the GT.
3. Startup the GTWIN and specify the communication condition.
The factory settings are as follows.
IP Address
192.168.1.5
Subnetmask
255.255.255.0
Default Gateway
192.168.1.1
Port No
9094
Note) Setting items such as IP address for the GT can be specified in the System Menu.
GTWIN setting
Network type: Ethernet
Title: Input an arbitrary title (Up to 38 one-byte
characters)
Computer:
Check Acquire IP address automatically”.
The default setting is to use the IP address
currently being used in the computer.
Click [OK] to finish the setting.
Note) When sing multiple Ethernet cards,
specify manually.
IP address: When it is not displayed, set the property of the TCP/IP in the items such as Network of the
control panel. IP address can be input or changed.
Note) The setting procedure varies depending on the OS used. For the details, refer to
the manual/help of the OS.
Port No.: Set to 0 or within the range of 1025 to 32767 in decimal.
For using it in the GTWIN, set it to 0.