Digital Camera Service Manual

19
7.2. When Replacing the Main PCB
After replacing the MAIN PCB, be sure to achieve adjustment.
The adjustment instruction is available at “software download” on the “Support Information from NWBG/VDBG-PAVC” web-site in
“TSN system”, together with Maintenance software.
7.3. Service Position
This Service Position is used for checking and replacing parts. Use the following Extension cables for servicing.
Table S1 Extension Cable List
CAUTION-1. (When servicing POWER/TOP PCB)
1. Be sure to discharge the capacitor on POWER/TOP PCB.
Refer to “HOW TO DISCHARGE THE CAPACITOR ON POWER/TOP PCB”.
The capacitor voltage is not lowered soon even if the AC Cord is unplugged or the battery is removed.
2. Be careful of the high voltage circuit on POWER/TOP PCB.
3. DO NOT allow other parts to touch the high voltage circuit on POWER/TOP PCB.
No. Parts No. Connection Form
1 VFK1950 FP6501 (SD/AFE) -CCD UNIT 33PIN 0.3 FFC
2 VFK1575C5125 FP9001 (MAIN) - POWER/TOP FPC 51PIN 0.3 FFC
3 VFK1974 FP9002 (MAIN) - LCD UNIT 4PIN 0.5 FFC
4 RFKZ0378 FP9003 (MAIN) - LCD UNIT 19PIN 0.5 FFC
5 VFK1951 FP9004 (MAIN) - BASE SU 39PIN 0.3 FFC
6 RFKZ0379 PP6501 (SD/AFE) - PS9001 (MAIN) 40PIN B to B