Schottky Barrier Diodes Specification Sheet

Schottky Barrier Diodes (SBD)
1
Publication date: April 2004 SKH00107BED
MA4X746 (MA746)
Silicon epitaxial planar type
For super high speed switching
For small current rectification
Features
Two isolated elements are contained in one package, allowing
high-density mounting
Forward current (Average) I
F(AV)
= 200 mA and Reverse voltage
V
R
< 50 V are achieved
Optimum for high frequency rectification because of its short
reverse recovery time t
rr
Low forward voltage V
F
and good rectification efficiency
Absolute Maximum Ratings T
a
= 25°C
Parameter Symbol Conditions Min Typ Max Unit
Forward voltage V
F1
I
F
= 30 mA 0.36 V
V
F2
I
F
= 200 mA 0.55
Reverse current I
R
V
R
= 50 V 200 µA
Terminal capacitance C
t
V
R
= 0 V, f = 1 MHz 30 pF
Reverse recovery time
*
t
rr
I
F
= I
R
= 100 mA 3.0 ns
I
rr
= 10 mA, R
L
= 100
Electrical Characteristics T
a
= 25°C ± 3°C
Parameter Symbol Rating Unit
Reverse voltage V
R
50 V
Repetitive peak reverse voltage V
RRM
50 V
Non-repetitive peak
Single I
FSM
1A
forward surge current
Double
*
0.75
Peak forward
Single I
FM
300 mA
current
Double
*
225
Forward current
Single I
F(AV)
200 mA
(Average)
Double
*
150
Junction temperature T
j
125 °C
Storage temperature T
stg
55 to +125 °C
Marking Symbol: M3M
Internal Connection
43
2
1
Bias Application Unit (N-50BU)
90%
Pulse Generator
(PG-10N)
R
s
= 50
Wave Form Analyzer
(SAS-8130)
R
i
= 50
t
p
= 2 µs
t
r
= 0.35 ns
δ = 0.05
I
F
= 100 mA
I
R
= 100 mA
R
L
= 100
10%
Input Pulse Output Pulse
I
rr
= 10 mA
t
r
t
p
t
rr
V
R
I
F
t
t
A
Unit: mm
1 : Cathode 1
2 : Cathode 2
3 : Anode 2
4 : Anode 1
EIAJ : SC-61 Mini4-G1 Package
2.90
+0.02
–0.05
0.16
+0.1
–0.06
0.4
±0.2
10˚
0.60
+0.10
–0.05
1.1
+0.2
–0.1
1.1
+0.3
–0.1
1.50
+0.25
–0.05
2.8
+0.2
–0.3
1.9
±0.2
(0.65)
(0.2)
(0.95)(0.95)
0 to 0.1
34
21
0.5R
Note)
*
: Value of each diode in double diodes used.
Note) 1. Measuring methods are based on JAPANESE INDUSTRIAL STANDARD JIS C 7031 measuring methods for diodes.
2. This product is sensitive to electric shock (static electricity, etc.). Due attention must be paid on the charge of a human body
and the leakage of current from the operating equipment.
3. Absolute frequency of input and output is 1 GHz.
4.
*
:t
rr
measurement circuit
Note) The part number in the parenthesis shows conventional part number.
This product complies with the RoHS Directive (EU 2002/95/EC).

Summary of content (3 pages)