3Specifications of Front Panel
31 Rotary switch(RSW)
By manipulating the RSWPr.0.03(selection of stiffness at real-time auto-gain tuning) was corrected by set-
ting the RSW, and can be changed from the front panel gain control.
Example)Pr0.03=8
RSW setting
The stiffness cor-
rection
Stiffness after
correction
LED Display
Parameter Pr0.03
is changed
PC ±0 8 Pc
Possible
+1 +1 9 9
+2 +2 10 10
+3 +3 11 11
+4 +4 12 12
+5 +5 13 13
+6 +6 14 14
+7 +7 15 15
- ±0 8 8
-7 -7 1 1
-6 -6 2 2
-5 -5 3 3
-4 -4 4 4
-3 -3 5 5
-2 -2 6 6
-1 -1 7 7
Impossible
*1 The setting value is 0 that the arrow of rotary switch upward direction. The value is increased
while the arrow is turned by clockwise direction.