CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 1 of 20 DATE 06.11.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 2 of 20 DATE 06.11.2006 Datum TABLE OF CONTENTS 1. Overview .............................................................................................................................. 3 1.1. Contents of the Evaluation Kit:................................................................................. 3 1.2. Hardware needed......................................
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 3 of 20 DATE 06.11.2006 Datum 1. OVERVIEW The EvalKit PAN4570 allows evaluation of the wireless module PAN4570. For a basic hardware evaluation the test software Ember Range Test Application V2.0 and the EmberTM embedded bootloader are programmed.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 4 of 20 DATE 06.11.2006 Datum Important: To install and run the programs you need Administrator rights on the test PC. Check for software updates at www.Ember.com. 2. SETTING UP THE EVALBOARD Plug a PAN4570 Carrierboard on one of the three 34-pins headers (B or C or D) as shown in Figures 1 and 2.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 5 of 20 DATE 06.11.2006 Datum 3.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 6 of 20 DATE 06.11.2006 Datum 4. OPERATION OF THE TESTBOARD If not already done please follow the basic setting up instructions as in Chapter 2 Check if the jumper plugs are set as indicated in Figure 2.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 7 of 20 DATE 06.11.2006 Datum For use of the P2 2mm contacts the black socket P2-X1 is the negative/ground contact and the red socket P2-X2 is the positive terminal. A linear regulator on the testboard regulates the input voltage down to the +5V DC board supply. A second linear regulator regulates the +5V DC down to the module VCC supply of 2,1/2,7/3,4Vdc. 5.2. D.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 No. REV. DS-Eval4570-2400 C PAGE Seite 8 of 20 DATE 06.11.2006 Datum EvalBoard PAN4570 PANASONIC’S CODE 6. SERIAL PORT The evalboard is equipped with a serial port connector, which is linked to UART1 (SCI1) of EM250. The S1 switch has to be set as follows: UART1 active S1 settings 1 2 3 4 5 6 7 8 ON off ON off off off off off (Table 3) 7.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 9 of 20 DATE 06.11.2006 Datum 8.2. UPLOAD OF EMBERZNET SAMPLE APPLICATIONS Insert the cd coming with this kit into the drive of your pc and navigate to the folder \software\images. Here two image files are provided for the >simple-lighting< application, simple-lighting-light.ebl and simple-lighting-switch.ebl.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 No. REV. DS-Eval4570-2400 C PAGE Seite 10 of 20 DATE 06.11.2006 Datum EvalBoard PAN4570 PANASONIC’S CODE 8.3. SELECTING THE HARDWARE PLATFORM The EmberZNet stack uses a EmberTM platform (EmberTM breakout board and RCM module), which is defined in a BOARD_HEADER file. This file is named dev0455.h and located in the folder ….\Ember\EmberZNet2.5.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 11 of 20 DATE 06.11.2006 Datum 8.4. EMBERTM INSIGHT ADAPTOR CONFIGURATION The EmberTM Insight Adaptor is used for programming and debugging of PAN4570 application software. As delivered the Adaptor is configured to support DHCP, in case your site is configured for static IP addresses the Adaptor has to be configured for static IP address as well.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 12 of 20 DATE 06.11.2006 Datum Connect the Ember™ Insight Adaptor to the SIF connector on the module carrierboard with the grey ribbon cable supplied with the Insight Adaptor. Please make sure that pin1 of the plug connects to pin1 of the header. 5.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 7. EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 13 of 20 DATE 06.11.2006 Datum The DOS entry window displays the progress of programming and finally displays >SUCCESS<. If not check again steps 3. to 5. Remove the connection of the Insight Adaptor to the PAN4570 carrierboard. Plug the PAN4570 carrierboard to the testboard and push RESET on the testboard PAN4570 is now ready to run the programmed software.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 14 of 20 DATE 06.11.2006 Datum 9.2. DEVELOPMENT OF APPLICATIONS For software development the Insight DesktopTM, a comprehensive integrated development environment (IDE) and C-language compiler toolchain from EmberTM Inc. is required.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 15 of 20 DATE 06.11.2006 Datum For more information on the items above see the website of EmberTM Inc. (www.ember.com) and the documentation included in the EmberTM Insight Desktop package as part of the EmberTM development kits. 9.4. TESTING FOR IEEE802.15.4 PARAMETERS The software on PAN4570 as delivered is the >EmberTM Range Test Application 2.0< (Version 1.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 16 of 20 DATE 06.11.2006 Datum 10. SCHEMATIC OF THE ISM RF TRANSCEIVER TESTBOARD 10.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 17 of 20 DATE 06.11.2006 Datum 10.2.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 No. REV. DS-Eval4570-2400 C PAGE Seite 18 of 20 DATE 06.11.2006 Datum EvalBoard PAN4570 PANASONIC’S CODE 10.3. PAN4570 CARRIERBOARD remarks: 1. PAN4570 is programmed per X2. European Technology Center Panasonic Electronic Devices (EUROPE) GmbH 2. R1, R2 and R4 are not mounted 3. R3 is mounted as pulldown resistor at SIF_MOSI (10k typ.) X1-34 S_MOSI is connected to ground X1-33. The pulldown res.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 11. [1] [2] [3] EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 19 of 20 DATE 06.11.2006 Datum RELATED DOCUMENTS Data sheet PAN4570 DS-4570-2400-102-01 19/05/2006 Data Sheet EmberTM EM250 Transceiver Version Rev. 5 IEEE Std. 802.15.4TM –2003 The following documentation can be found as part of the installed EmberZNet package: [4] [5] [6] [7] [8] [9] 12.
CLASSIFICATION Einstufung SUBJECT Thema CUSTOMER’S CODE EvalPAN4570 14. EvalBoard PAN4570 PANASONIC’S CODE No. REV. DS-Eval4570-2400 C PAGE Seite 20 of 20 DATE 06.11.2006 Datum GENERAL INFORMATION This product description does not lodge the claim to be complete and free of mistakes. Please contact the related product manager in every case. If we deliver samples to the customer, these samples have the status Engineering Samples. This means, the design of this product is not yet concluded.