TECHNICAL CHARACTERISTICS THE HOT WATER TANK WITH
HEATING PUMP
HE - Heat exchanger
1) Heating of domestic water from 10 °C to 45 °C with the inlet temperature of the heating medium of 80 °C
and flowrate of 3000 l/h.
(*) Heating of water to 55 °C at inlet air temperature of 7 °C, 89% humidity and inlet temperature of water of
10 °C; in accordance with the EN16147 standard.
Model PAW-
DHWM200ZC
PAW-
DHWM300ZC
PAW-
DHWM300ZE
Volume [l] 200 285 280
Rated pressure [MPa] up to 1,0 (10)
Weight / Filled with water [kg] 120 / 320 149 / 434 166 / 446
Anti-corrosion protection of tank Enameled / MG Anode
HE heated surface - lower [m
2
] 1,05 1,60 1,60
HE heated surface - upper [m
2
] - - 1,09
HE volume - lower [l] 6,6 10 10
HE volume - upper [l] - - 6,8
Heating power of HE - lower
1)
[kW] 25,8 42,7 42,7
Heating power of HE - upper
1)
[kW] - - 26,9
Temperature of the heating medium in HE [°C] 5 to 85
Insulation thickness [mm] 57
Degree of protection IP 21
Max connected load [W] 620
Voltage 230 V / 50 Hz
Adjusted water temperature [°C] 55
Legionella control programme [°C] 65
Operation zone - air [°C] 7 to 35
Max volumetric flow rate of air [m
3
/h] 480
Max acceptable pressure drop in the pipeline
(volumetric flow rate of air 480 m
3
/h) [Pa]
90
Refrigerating agent R 134a
Quantity of coolant [g] 780
*Heating time A7 / W10-55 [h:min] 7:22 11:10 11:10
*Energy consumption during heating A7 / W10-55 [kWh] 3,25 4,76 4,76
Type of measured cycle of emissions L XL XL
*Energy consumption in the selected cycle
of emissions A7/W10-55 [kWh]
4,9 7,26 7,26
*COP
DHW
in the selected cycle of emissions A7 / W10-55 2,6 2,8 2,8
Max quantity of usable water (min 40 °C) [l] 252,08 345,76 345,76
Sound power / Sound pressure at 1m [dB(A)] 56,7 / 44 56,7 / 44 56,7 / 44