Network Operating Instructions Network Interface Unit WJ-NT314

25
2 GB
1 GB
512 MB
256 MB
128 MB
64 MB
Size of SD
memory card
Approx. 32 000 pics
Approx. 16 000 pics
Approx. 8 000 pics
Approx. 4 000 pics
Approx. 2 000 pics
Approx. 1 000 pics
Approx. 36 000 pics
Approx. 18 000 pics
Approx. 9 000 pics
Approx. 4 500 pics
Approx. 2 250 pics
Approx. 1 125 pics
Approx. 38 000 pics
Approx. 19 000 pics
Approx. 9 500 pics
Approx. 4 750 pics
Approx. 2 375 pics
Approx. 1 187 pics
Approx. 40 000 pics
Approx. 20 000 pics
Approx. 10 000 pics
Approx. 5 000 pics
Approx. 2 500 pics
Approx. 1 250 pics
Approx. 42 000 pics
Approx. 21 000 pics
Approx. 10 500 pics
Approx. 5 250 pics
Approx. 2 625 pics
Approx. 1 312 pics
5 (Normal) 6 7 8 9 (Low)
Image quality
Size of SD
memory card
Image capture size: QVGA
2 GB
1 GB
512 MB
256 MB
128 MB
64 MB
Approx. 24 000 pics
Approx. 12 000 pics
Approx. 6 000 pics
Approx. 3 000 pics
Approx. 1 500 pics
Approx. 750 pics
Approx. 26 000 pics
Approx. 13 000 pics
Approx. 6 500 pics
Approx. 3 250 pics
Approx. 1 625 pics
Approx. 812 pics
Approx. 27 000 pics
Approx. 13 500 pics
Approx. 6 750 pics
Approx. 3 375 pics
Approx. 1 687 pics
Approx. 843 pics
Approx. 28 000 pics
Approx. 14 000 pics
Approx. 7 000 pics
Approx. 3 500 pics
Approx. 1 750 pics
Approx. 875 pics
Approx. 30 000 pics
Approx. 15 000 pics
Approx. 7 500 pics
Approx. 3 750 pics
Approx. 1 875 pics
Approx. 937 pics
0 (Super fine) 1 (Fine) 2 3 4
Image quality
Configure the settings relating to the RS-485 port [RS485 setup]
Click the [RS485 setup] tab on the "Basic setup" page. (page 20)
The settings relating to the RS-485 port such as the communication speed can be configured on this page.
[Communication speed]
Select the communication speed for RS-485 port from
the following.
9600/19200/38400 bps
Default setting: 38400 bps
[Data bit]
Select "7 bit" or "8 bit" to determine the data bit for the
RS-485 port.
Default setting: 8 bit
[Parity check]
Select the parity check method for RS-485 port from the
following.
NONE: Parity check is not performed.
ODD: Parity check is performed for odd parity bits.
EVEN: Parity check is performed for even parity bits.
Default setting: NONE
[Stop bit]
Select "1 bit" or "2 bit" to determine the stop bit for the
RS-485 port.
Default setting: 1 bit