Network Operating Instructions Network Interface Unit WJ-NT314

63
Cannot access from the
browser.
The buttons on the browser
are displayed out of align-
ment.
Is the same IP address provided to other devices?
Are there contradictions between the address and the
network subnet to be accessed?
<When the unit and the PC are connected in the
same subnet>
Are the IP addresses of the unit and the PC set in a
common subnet? Or is "Use Proxy Server" for the set-
tings of the browser checked?
When accessing the unit in the same subnet, it is rec-
ommended to enter the address of the unit in the
"Dont Use Proxy For These Addresses" box.
<When the unit and the PC are connected in the dif-
ferent subnet>
Is the IP address of the default gateway set for the
unit correct?
The buttons may not be displayed orderly if the font
setting of Windows has been changed from the
default setting.
Use with the default font setting.
47
Some contents are not dis-
played on the browser.
Reload the contents by pressing the [F5] key.
Cannot close the authentica-
tion window.
Are the correct user name and password entered?
Confirm the correct user name and password.
The line speed settings may be not the same between
the unit and the hub, for example, 100M BASE-TX
Full for the unit and 100M BASE-TX Half, etc. Some
hubs change the line speed automatically depending
on the network traffic and it may cause configuration
errors. Check the line speed settings of both the unit
and the hub, and configure the line speed settings of
both to conform them.
46, 47
Browser disconnection
sometimes occurs.
Network performance is
poor.
The settings relating to the bit rate may be beyond the
maximum network performance.
Lower the value/rate of the settings relating to the bit
rate such as the refresh interval.
26
Reference
pages
Cause/solution
Symptom