The model shown is WV-CW244FE. Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. DEUTSCH ENGLISH WV-CW240S WV-CW244FE FRANÇAIS Model No.
The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance. ENGLISH VERSION CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN Turn the power off at the mains to disconnect the main power for all unit. CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK). NO USER SER-VICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
FOR YOUR SAFETY PLEASE READ THE FOLLOWING TEXT CAREFULLY. WARNING: This apparatus must be earthed. IMPORTANT Wij verklaren als enige aansprakelijke, dat het product waarop deze verklaring betrekking heeft, voldoet aan de volgende normen of andere normatieve documenten, overeenkomstig de bepalingen van Richtlijnen 73/23/EEC en 89/336/EEC. The wires in this mains lead are coloured in accordance with the following code.
CONTENTS FEATURES ..................................................................................................................................................................... 5 PREFACE ....................................................................................................................................................................... 5 PRECAUTIONS ........................................................................................................................................
PREFACE The WV-CW240 series is a 1/3” CCD colour camera designed for use in a video surveillance system. The camera features a high picture quality thanks to the use of digital signal processing LSIs, and easy installation. FEATURES • Mounting method: Flush mounting/WV-CW244FE, Surface mounting/WV-CW240S • Signal processing: Automatic Light Control (ALC), Automatic Gain Control (AGC), Automatic Tracing White Balance (ATW), etc.
PRECAUTIONS 1. This product should be installed and connected by qualified service personnel or system installers in conformity with local codes. 7. Clean the lens faceplate with care. Do not clean the lens with strong or abrasive detergents. Use lens tissue or a cotton tipped applicator and ethanol. 2. Use a class 2 power source supplying 12 V DC or 24 V AC. 8. Never face the camera towards the sun. Do not aim the camera at bright objects.
MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS qw 2nd transport protection screw (Red) Space for heater unit !1 ON LL INT* ON 2 OFF* AP SOFT SHARP* r 3 BLC e ON OFF 1 SYNC t * Default setting !0 o i uy q Focus lock lever Fixes the focus position after adjusting. e Zoom lock lever Fixes the zoom position after adjusting. w Tilting lock screw Fixes the tilting position after adjusting. r Panning table Adjusts the panning angle of the camera.
t Azimuth adjuster Adjusts the azimuth angle to obtain a level image. !1 Heater power connector Supplies power to the optional heater unit when it is built in the camera. Connect here a harness sticking out from the heater unit. y Pan lock screw Fixes the panning position after adjusting. u Video jack (3.5-diam. mini jack) For connecting an LCD monitor to adjust the camera images. Use an L-type plug to save space. i Aperture Level Selector SHARP: Sharpens the image outline.
!2 Dome cover !3 Video output cable with BNC connector Connects with the video connector of the monitor. !2 !4 Camera power cable For WV-CW240S: Supplies 220 V - 240 V AC 50 Hz to the camera. The camera will supply the optional heater unit with 24 V AC power that is transformed from the supplied 220 V - 240 V AC. For WV-CW244FE: Supplies 24 V AC 50 Hz or 12 V DC to the camera. The black and grey cords will supply 24 V AC to the optional heater unit from an external power source.
INSTALLATION ■ Installation Plans & Preparations 1. Space Prepare a space larger than ø160 mm. ● WV-CW244FE 2. Flush-mount hole Drill a hole having a 95 mm diameter on the wall or ceiling. “F” stands for flush mounting. This model can be installed on the wall or ceiling prepared with a 95 mm diameter hole. 3. Attachment fixing screws Locally procure four screws (M4) that are suitable for the installation surface to fix the attachment on the surface. 74 mm (2-15/16") 4.
● WV-CW240S “S” stands for surface mounting. This model can be installed on the surface of the wall or ceiling using the supplied bracket.
■ Mounting the Camera 1. Space Prepare a space larger than ø160 mm. ● Disassembling of the camera 2. Bracket Fixing Screws To fix the bracket, procure four M4 screws suitable for the surface and structure of the wall/ceiling. 1. Remove the dome cover by loosening three tamper-proof screws using the supplied bit. 3. Attachment Fixing Screws Four screws are supplied as standard accessories. 4. Cable route • When routing cables through the wall/ceiling, drill a hole as shown in the figure.
● Mounting the camera 2. Remove the two red-coloured screws provided for transport protection using a Philips screwdriver. 1. Fix the camera to the installation surface. WV-CW244FE • Fix the attachment on the surface using four screws (locally procured). • Place the camera on the attachment and rotate it clockwise. • Fasten the camera lock screw. WV-CW240S • Fix the bracket on the surface using four screws (locally procured). • Fix the attachment on the bracket using four screws (supplied).
■ Connections Caution: Be sure to connect the GND (grounding) lead of the camera and grounding terminal of the power supply when using a 24 V AC power source. ● Video Output Connection Connect the video output connector to the monitor or other system device with the procured coaxial cable. The maximum extensible length is shown in the table.
● 10.5 V DC ≤ VA − 2(R x I x L) ≤ 16 V DC L : Cable length (m) (ft) R : Resistance of copper wire (Ω/m) (Ω/ft) VA : DC output voltage of power supply unit Cable Length and Wire Gauge 24 V AC The recommended cable length and thickness are shown in the table for reference. The voltage supplied to the power terminals of the camera should be within 19.5 V AC and 28 V AC. I : DC current consumption (A). See specifications. Recommended wire gauge for 24 V AC line.
■ Image Adjustment 1. Connect an LCD monitor to the video jack. You can manually adjust the pan/tilt/azimuth angles, focus, and zoom while observing the connected monitor. 2. Pan/tilt/azimuth adjustment • Loosen the two screws locking the pan and tilt tables. • Pan and tilt the table to aim the camera at what you need to watch. • Turn the azimuth adjuster to obtain a level image. • Tighten the two screws after adjusting. Variable angles plus or minus 75 ° (max.
3. • • • ● Waterproof Process Zoom Unlock the zoom lever. Move the lever to adjust the zoom. Lock the lever. When necessary, apply waterproof process to protect the camera from water soak. Using butyl rubber tapes is recommended, not using ordinary vinyl tapes. 1. Power cord First, tape the individual wires, finally all of them as a whole. FAR TELE NEAR WIDE Power cord Zoom lock lever Focus lock lever 4. • • • 2. Connector junctions Tape the BNC-BNC junction point. Focus Unlock the focus lever.
SPECIFICATIONS Pick-up device: Scanning area: Scanning: Horizontal: Vertical: Synchronization: Video output: Horizontal resolution: Signal-to-noise ratio: Minimum illumination: Detail: White balance: Lens Mount: Lens Focal length: Maximum aperture ratio: Angular field of view: Focusing range: Ambient operating temperature: Ambient operating humidity: Power source and Power consumption: 752 (H) x 582 (V) pixels, Interline transfer CCD 4.8 (H) x 3.
WV-CW240S: Dimensions: Weights: 220 V - 240 V AC 50 Hz 4.1 W (Camera) 13 W (with heater) WV-CW244FE: 160.5 mm (H) 154 mm (D) 6-5/16" (H) 6-1/16" (D) WV-CW240S: 161 mm (H) 160 mm (D) 6-3/8" (H) 6-5/16" (D) WV-CW244FE: 1.4 kg (3.1 lbs.) WV-CW240S: 2.1 kg (6.4 lbs.) Weights and dimensions indicated are approximate. Specifications are subject to change without notice. STANDARD ACCESSORIES Operating Instructions (this document) ............................................. 1 pc.
OPTIONAL ACCESSORIES Heater unit .........................................................................................
OPTIONAL HEATER UNIT ■ Optional Heater Unit WV-CW3HE ● Introduction Installing this heater unit enables the camera to operate under in a low-temperature environment of –30°C (–22°F). The heater turns on automatically when the temperature inside the camera drops below +10°C (50°F) and turns off when it rises. A small fan inside the unit will minimize condensation on the surface of the dome cover caused by changes in ambient temperature unless temperatures change too rapidly.
● Installation Adhesive tape 1. Open the dome cover. (See Disassembling the camera.) Fold 2. Place the heater unit in the camera and fix it with the supplied screw. 3. Insert the harness into the heater unit connector of the camera. 4. Fold the desiccant pack in half, and attach it with adhesive tape to point "A" shown in the figure. Note: Attach the desiccant pack so that it does not block ventilation holes or hang over the top of Point “A” the wall. (inside the wall) 5.
Printed in China Gedruckt in China Imprimé en Chine Impreso en China Stampato in Cina 2003 © Matsushita Electric Industrial Co., Ltd. All rights reserved.