Acculink DSU/CSU Data Service Unit Models 3160-A4, 3161, 3164-A2, and 3165-A4 Operator's Guide

4. Configuration
3160-A2-GB24-10 March 2001
4-15
Setting the IP Address
The IP address is the address used by the SNMP or Telnet system to access the
DSU/CSU (see Appendix G,
IP Network Addressing Scenarios
). For DSU/CSUs
using PPP, the IP address can be negotiated if the network device (e.g., router or
SNMP manager) supports such negotiation. The IP address is composed of four
bytes, each represented by three decimal digits (
xxx.xxx.xxx.xxx
).
The IP address is set for the MODEM port, the COM port, or, for the Model 3164
only, the AUX port (with LAN Adapter or daisy chain), depending on which one has
been chosen as the SNMP or Telnet communication link. The example below
shows an IP address of 010.155.111.222 being set for the COM port. You can use
the same principles to assign any valid value. Valid values are 000126 and
128223 for the first byte, and 000255 for the remaining bytes.
Procedure
To assign an IP address to the COM port:
1. From the top-level menu screen, select Cnfig.
2. Select the configuration option set to be copied into the Edit area by using the
appropriate Function key. Use the scroll keys, if necessary.
3. Select Edit.
4. From the Edit screen, press the key until the Mgmt selection appears on
the screen.
5. Select Mgmt.
6. From the Mgmt Config screen, select Gen.
7. Press F1 (Next) until the Com IP Adr configuration option appears.
F1
F2
F3
Edit:
User Alarm Mgmt
F1
F2
F3
Mgmt Config:
Gen Trap