- Compumotor OEM650/OEM650X OEM350/OEM350X Drive and Drive/Indexer User Guide

OEM650/OEM650X INSTALLATION
31
Sizing Power Supply
Table 2-14 contains power ratings to help system designers size a
power supply. Combinations of motors and current levels other than
those shown may result in power values that are not recommended.
Connection
OEM57 motors may be configured in parallel or series. OEM83
motors must be wired in parallel. Refer to the OEM650 Quick Test.
Motor Size Motor Motor Heat + Drive Supply
(@75VDC) Current Avg. Shaft Power Heat Total**
OEM57-40-MOS 2.65A 56 Watts 9 Watts 65 Watts
OEM57-40-MOP 5.3A 56 Watts 19 Watts 75 Watts
OEM57-51-MOS 3.3A 75 Watts 11 Watts 86 Watts
OEM57-51-MOP 6.6A 75 Watts 25 Watts 100 Watts
OEM57-83-MOS 3.8A 86 Watts 13 Watts 99 Watts
OEM57-83-MOP 7.5A 86 Watts 31 Watts 117 Watts
OEM83-62-MO* 4.4A 113 Watts 15 Watts 128 Watts
OEM83-93-MO* 5.6A 133 Watts 20 Watts 153 Watts
OEM83-135-MO* 6.9A 155 Watts 27 Watts 182 Watts
S: Series Configuration P: Parallel Configuration
* 34 size motors are internal wired in Parallel ** User must supply this level of wattage
Table 2-14. Power Sizing
Use the following equation to determine drive heat.
Drive Heat
(Watts) = (0.31) (I
M
2
) + (1.13 I
M
) + 3 I
M
=
Motor Current
Calculations
To convert watts to horsepower, divide by 746
To convert watts to BTU/hour, multiply by 3.413
To convert watts to BTU/minute, multiply by 0.0569
Motor Type
OEM650/OEM650X motors are custom-made for use with these
drives and drive/indexers. They are not available as a standard
model from any other manufacturer. These motors are designed for
low loss at rest and at high speed. Motors in the same frame size
from other manufacturers may sustain considerably higher iron
losses than an OEM650/OEM650X motor. OEM motors are wound
to render inductances within a range suitable for OEM Series prod-
ucts. If you do not use an OEM Series motor, you should consult
Compumotor's Applications Engineering Department for assistance
(800-358-9070). OEM650s/OEM650Xs are designed to run 2-phase
PM step motors only. Do not use variable reluctance or DC motors.