Installation Manual

Page 9
301 Fulling Mill Road, Suite G ©Copyright 2008 by On-Q/Legrand,
Middletown, PA 17057 Inc All Rights Reserved.
(800)-321-2343 www.onqlegrand.com
Selective Call Door Unit(s)
The procedure to trim-out the Door Unit(s) is as
follows:
NOTE: Make sure that the included weather
proofing gasket is placed as shown in Figure 8.
As shown in Figure 8, the first step to
installing the Selective Call Door Unit is to
place the included rear gasket against the
gang or back box, and secure the gasket in
place with the included mounting bracket.
NOTE: Insure that the mounting bracket is
installed with the center tab pointed up, as
the Door Unit will be “hung” from this tab in
a later step.
NOTE: There are slotted holes in the mounting bracket to allow for leveling of the Door
Unit in case the gang or back box was installed off level.
Use the four provided screws to attach the mounting bracket to the gang or back box.
Pull the Cat 5 cable from the enclosure through the mounting bracket and terminate the cable
with an RJ45 plug and insert the plug into the RJ45 jack on the rear of the Door Unit (see
Figure 9). Follow the T568A standards described in Figure 3.
Hang the Door Unit from the top tab on the mounting bracket insuring the front gasket is in
place and against the mounting bracket.
Use the provided 1/16” allen wrench to tighten the two set screws at the bottom of the Door
Unit.
NOTE: There is a four position terminal
block on the rear of the Door Unit that
can be utilized for two different
purposes (see Figure 10). The CHIME
output is a normally open dry contact
closure used to ring a customers 3
rd
party door chime when the Door Unit
button is pressed. The SENSOR input
is reserved for a future application.
rear
gasket
center tab
mounting
bracket
Figure 9
Figure 8
RJ45
jack
front gasket
Figure 10
set screws