Installation Manual

Page 10
301 Fulling Mill Road, Suite G ©Copyright 2008 by On-Q/Legrand,
Middletown, PA 17057 Inc All Rights Reserved.
(800)-321-2343 www.onqlegrand.com
Selective Call Intercom Distribution Module
The procedure to install the Intercom Distribution Module is as follows:
As shown in Figure 11, there is an “ADDRESS” jumper block located at the top of the rear of
the Selective Call Intercom Distribution Module. This jumper block is used to select the Master
module, and up to three Slave modules when cascading Distribution Modules. Each Selective
Call Distribution Module is shipped with the jumper in the Master position. Use the diagram to
correctly position the jumper to give each Distribution Module a unique address.
Also as shown in Figure 11, there is also a four position terminal block located on the lower
left corner of the rear of the Selective Call Intercom Distribution Module. These are Open
Collector outputs labeled “A” and “B” (ground and output connectors for each). At any
Room Unit, you can configure the “A” Door Strike (“Release”) and/or “B” Alert (“Trigger”)
outputs to be enabled or disabled. Figure 12 shows an example of electronic door release
and/or trigger wiring and Figure 13 shows the screen sequence to enable these functions.
Figure 11
GND GNDOUT OUT
B
A
Door
Strike
Door
Strike
Relay
SCI
Module
(rear view)
Power
Supply
To LCD Module
to wake up LCD Display
and show front door
camera when door bell
is pushed
GND GNDOUT OUT
B
A
Door
Strike
Door
Strike
Relay
SCI
Module
(rear view)
Power
Supply
To LCD Module
to wake up LCD Display
and show front door
camera when door bell
is pushed
GND GNDOUT OUT
B
A
SCI
Module
(rear view)
Wake ups LCD Display and
shows front door camera
when door bell is pushed
GND
VID_1
TRG
LCD
Module
(rear view)
GND GNDOUT OUT
B
A
SCI
Module
(rear view)
Wake ups LCD Display and
shows front door camera
when door bell is pushed
GND
VID_1
TRG
LCD
Module
(rear view)
Figure 12
Door Strike Wiring
LCD Trigger Wiring