Installation Manual

Page 16
301 Fulling Mill Road, Suite G ©Copyright 2008 by On-Q/Legrand,
Middletown, PA 17057 Inc All Rights Reserved.
(800)-321-2343 www.onqlegrand.com
Door Unit Hands-Free Reply Options
The Reply Options screen (see Figure 36) is used to select the amount of time all Door Units
remain in hands-free reply mode. The options are 60 seconds, 30 seconds, 15 seconds, 10
seconds (the default), 5 seconds, or disabled (see Figure 37).
Door Options
The Installer Setup Door Options (see Figure 38) is where you enable or disable the “A” and
“B” open collector output terminals on the rear of the SCI Distribution Module. Notice it is
specific to a particular Door Unit (see Figure 39). The “A” output is for an Electronic Door
Release (see Figure 40) and the “B” output is for a trigger output that may be tied to a doorbell
button push action, such as turn on the porch light when someone presses the door bell, as
shown in Figure 41.
ROOM1
INSTALLER SETUP
Door Options
Firmware Info
System Reset
Room Options
Disc. Settings
Reply Options
ROOM1
INSTALLER SETUP
Door Options
Firmware Info
System Reset
Room Options
Disc. Settings
Reply Options
REPLY OPTIONS
10 sec
Door Reply:
BACK
REPLY OPTIONS
10 sec
Door Reply:
BACK
Figure 36
Figure 37
ROOM1
INSTALLER SETUP
Reply Options
Door Options
Firmware Info
System Reset
Room Options
Disc. Settings
ROOM1
INSTALLER SETUP
Reply Options
Door Options
Firmware Info
System Reset
Room Options
Disc. Settings
PATIO OPTIONS
DOOR OPTIONS
Select Unit:
DOOR1
BACK
PATIO OPTIONS
DOOR OPTIONS
Select Unit:
DOOR1
BACK
PATIO OPTIONS
DOOR 1
Release: ENABLE
BACK
Trigger: DISABLE
PATIO OPTIONS
DOOR 1
Release: ENABLE
BACK
Trigger: DISABLE
Figure 38
Figure 39 Figure 40
GND GNDOUT OUT
B
A
Door
Strike
Door
Strike
Relay
SCI
Module
(rear view)
Power
Supply
To LCD Module
to wake up LCD Display
and show front door
camera when door bell
is pushed
GND GNDOUT OUT
B
A
Door
Strike
Door
Strike
Relay
SCI
Module
(rear view)
Power
Supply
To LCD Module
to wake up LCD Display
and show front door
camera when door bell
is pushed
GND GNDOUT OUT
B
A
SCI
Module
(rear view)
Wake ups LCD Display and
shows front door camera
when door bell is pushed
GND
VID_1
TRG
LCD
Module
(rear view)
GND GNDOUT OUT
B
A
SCI
Module
(rear view)
Wake ups LCD Display and
shows front door camera
when door bell is pushed
GND
VID_1
TRG
LCD
Module
(rear view)
Figure 41
Door Strike Wiring LCD Trigger Wiring