Data Sheet

LA6-W18D-15_26
Setup Parameters
This mode has parameters that can be set up as shown in the following table.
Setup Range Setting Index Description
Every Group
Display
Repeats
W
hen even the last set-up pattern changes and display time is exceeded, it is either
selected to return to the head pattern of the group, or is considered as the last pattern.
Display Time
Unit
Every 1 second and every 0.1 seconds are selected for the display time in units, to be set
up for each pattern.
STOP Input
Operation
A ST
OP input can be selected for four operations when turned “ON.
Every Pattern
Display Time Select the time until a pattern changes to the next pattern.
LED Lighting/
Flashing
Select all LEDs to turn on or ash. Flashing rates are selectable from 30 times per min-
ute, 60 times per minute, or 120 times per minute.
A
larm Tone Alarm Silence or one tone can be selected from 11 varieties.
Every Tier LED Color LED lights On or O can be selected.
Group Input Conversion Table
For inputs 1-4, group No. in the combination of ON/OFF can be entered as indicated in the “Time-trigger” mode operation
example.
Table 5. Time-trigger mode Input Conversion Table
Group No. Input 1 Input 2 Input 3 Input 4
1 ON
2 ON
3 ON ON
4 ON
5 ON ON
6 ON ON
7 ON ON ON
8 ON
9 ON ON
10 ON ON
11 ON ON ON
12 ON ON
13 ON ON ON
14 ON ON ON
15 ON ON ON ON
An empty cell indicates the “OFF” condition.
Note
* In the “Time-trigger” mode, an “ON” state on input 5 (one shot pulse) can make a pattern change; an “ON” state on input
6 can cause the alarm to mute; and an “ON” state on input 7 can cause a “Clear” (reset of the operation).