Data Sheet

LA6-W18D-17_26
Group Input Conversion Table
For inputs 1-4, group No. in the combination of ON/OFF can be entered as indicated in the “Pulse-trigger” mode operation
example.
Table 6. “Pulse-trigger mode Input Conversion Table
Group No. Input 1 Input 2 Input 3 Input 4
1 ON
2 ON
3 ON ON
4 ON
5 ON ON
6 ON ON
7 ON ON ON
8 ON
9 ON ON
10 ON ON
11 ON ON ON
12 ON ON
13 ON ON ON
14 ON ON ON
15 ON ON ON ON
An empty cell indicates the “OFF” condition.
“Pulse-trigger mode Operation Example
The following are examples of the “Pulse-trigger” mode operation.
In addition to trigger input and pattern changes, the gure shows the operation of the “Mute” input.
* The “Pulse-trigger” mode operating state is an example for setting data.
Note
* With a “Pulse-trigger” mode, an “ON” state on input 5 (one shot pulse) can make a pattern change; an “ON” state on
input 6 can cause the alarm to mute; and an “ON” state on input 7 can cause a “Clear” (reset of the operation).
Operating
Condition
LED OFF
1/- 1/1
1/2
1/3
... 1/60 1/61 1/62 1/63
OFF
Buzzer
Mute Mute Mute
Signal Input
Input 1
Input 2
Input 3
Input 4
Input 5 (STOP)
Input 6 (Mute)
Input 7 (Clear)