Data Sheet

LA6-W18D-18_26
In addition to trigger input and pattern changes, the gure shows the operation of the “Mute” input and the “Clear” input.
5.2.3. “Single-display mode
There are 31 group varieties with the product’s internal memory that can be used in combination of ON/OFF inputs from signal
wire inputs 1-5 to operate the LED display colors. Although the Flashing/Alarm functions can be used, the LED wave-like color
ow, etc., cannot be used.
The setup for each group can be made in the “EDITOR for LA series” software application (Visit our homepage at http://www.
patlite.com/ to download the software application and other features for the LA6.).
Setup Parameters
This mode has parameters that can be set up as shown in the following table.
Setup Range Setting Index Description
Every Group LED Lighting/Flashing Select all LEDs to turn on or ash. Flashing rates are selectable from 30
times per minute, 60 times per minute, or 120 times per minute.
Alarm Tone Alarm Silence or one tone can be selected from 11 varieties.
Every Tier LED Color LED lights On or O can be selected.
Note
The one shot trigger input pulse acquires only the rise-time of the input. Refer to
“7.1. Basic Signal Input Time Chart
for
more details.
Operating
Condition
LED OFF
1/- 1/1
1/2
1/3
... 1/60 1/61 1/62 1/1 1/2
OFF
Buzzer
Mute
Mute
Mute
Signal Input
Input 1
Input 2
Input 3
Input 4
Input 5 (STOP)
Input 6 (Mute)
Input 7 (Clear)