Data Sheet

LA6-W18D-19_26
Group Input Conversion Table
For inputs 1-5, Group numbers in combination of ON/OFF can be entered as indicated in the “Single-display” mode operation
example.
Table 7. “Single-display” mode Input Conversion Table
Group No. Input 1 Input 2 Input 3 Input 4 Input 5 Group No. Input 1 Input 2 Input 3 Input 4 Input 5
1 ON 17 ON ON
2 ON 18 ON ON
3 ON ON 19 ON ON ON
4 ON 20 ON ON
5 ON ON 21 ON ON ON
6 ON ON 22 ON ON ON
7 ON ON ON 23 ON ON ON ON
8 ON 24 ON ON
9 ON ON 25 ON ON ON
10 ON ON 26 ON ON ON
11 ON ON ON 27 ON ON ON ON
12 ON ON 28 ON ON ON
13 ON ON ON 29 ON ON ON ON
14 ON ON ON 30 ON ON ON ON
15 ON ON ON ON 31 ON ON ON ON ON
16 ON An empty cell indicates the “OFF” condition.
“Single-display mode Operation Example
The following are examples of the “Single-display” mode operation.
Note
* For the “Single-display” mode, with an “ON” status on input 6, a “Clear” (reset of the operation) can be executed, and
an “ON” status on input 7 can cause the alarm to be muted.
Operating
Condition
LED OFF
Group 1
OFF
Group 2
Group 10 Group 21
Clear Group 1
OFF
Buzzer
Mute
Mute Mute
Mute
Signal Input
Input 1
Input 2
Input 3
Input 4
Input 5 (STOP)
Input 6 (Mute)
Input 7 (Clear)