Data Sheet

LA6-W18D-23_26
For a detailed verication of the current version, the “EDITOR for LA series” software application can be used to check from the
PC.
If there is no personal computer, etc., available in its environment, contact your nearest Patlite Sales Representative and tell them
the status of LED tiers displayed to determine the current rmware version.
To exit from the “Version Conrmation” status, pressing the Multiple-function Button for about 3 seconds, or leaving it for 15
seconds untouched, will automatically cause it to return to it’s normal operation.
5.3.2.3. Product Initialization
The ashing speed of the white LED gradually becomes faster while holding the Multiple-function Button down until the White
LED is in its full ashing state. The rst ashing lasts about 15 seconds before the ash rate increases, and by continuing to push
the Multiple-function Button, the White LED goes out after 10 seconds and Initialization (product returns to “Signal Tower” mode
and values are back to factory default) is completed.
Initialization
Complete
Continue pushing button until
initialization is complete.
About 15 sec. About 5 sec. About 5 sec.
The White LED ashing gradually becomes faster
When the White
LED goes out,
initialization is
complete.
Flashing
White
Slow-flashing
White
Fast-flashing
White
Note
If the Multiple-function” Button is released before initialization is completed, it returns to the “Signal Tower” mode.
A
fter pushing the “Multiple-function” Button, the standard time to completely return to factory default is 30 seconds.