7. Time Chart
A signal input and its input signal recognition are determined based on the time chart shown below. This product is roughly
classied into two input signals, as indicated from the following contents.
- Standard Input Signal: All input signals, except a trigger input, are level hold inputs.
- Trigger Input Signal: It is a one shot input. (Only for the “Pulse-trigger” mode)
Refer to
“5. Operating Directions”
for details.
In addition, the signal input holding time (data lead time) of this product is common to all signal inputs (except for the Multi-
function Button).
Data lead time is 60 milliseconds.
7.1. Basic Signal Input Time Chart
If an input signal status is maintained by the data lead time indicated for this product, the input status is decided inside the
product.
7.2. Trigger Input Signal Time Chart
Unlike other inputs, the trigger input in the “Smart Mode” turns into a one shot input. As the time in detection rises, and is
maintained, the next detection is not recognized.
Turns on during this period.
Recognized as “ON”
during this period.
50ms 50ms
Input Signal
Inside Product
The trigger input should
be two 50ms inputs.
Recognized as
one trigger input.
If the trigger has not been turned “OFF” at
least once, an input will not be recognized.
Trigger Signal
Inside Product
100ms
50ms
50ms