3.2 CAR DOOR POWER CONNECTIONS
Connect controllers in accordance with local electrical codes.
Power branch circuit should come from machine room disconnect
10 amp circuit for each line of doors. Use #14AWG [2mm]
copper wire for power connection.
• ON/OFF switch disconnects both lines
• If neutral is not used, main disconnect must break both lines.
WARNING
HIGH VOLTAGES
Read Safety Warning before
attempting to use this controller
CONDUIT AND SHIELD
GROUNDING LUG
!
The enclosure supplied is non-
metallic and does not provide
grounding between conduit
connections. Use grounding
bushings or jumper wires.
Power
GND L1 L2 / N
1 Ø Power
208-240V AC
5.5A, 50/60 Hz
Car Door