Installation Instructions

21
FREIGHT DOORS
I
CAR GATES
I
CAR ENCLOSURES
TECHNICAL SUPPORT 1-800-787-5020 ext 275
THE PEELLE COMPANY
®
Guide No.
Date:
224-EN
WIRELESS CONTROLLER
INSTALLATION & INTERFACE GUIDE
May 13 / 2021
4.2 LANDING DOOR
Ensure Landing Door interlock is mechanically unlocked. Ideally car is level at oor with retiring cam extended
• Ensure all EUD switches are set to the SET position
1. Turn power ON
9. Press and hold the CLOSE button to close
the door.
2. Set AUTO<>IND switch to IND
10. Set AUTO<>IND switch to AUTO.
3. Using the OPEN and CLOSE buttons, ensure the landing door operators are phased for correct
rotation. If a motor rotates in the wrong direction, switch any two of the three motor wires.
4. To begin, cycle through parameters by pressing the - & + buttons. Once the desired parameter
is displayed, press the ENTER button to access the setting for that parameter. Change the setting
by pressing the - & + buttons. Once the desired setting is displayed, press the ENTER button to
save the setting. Parameters can only be modied in IND mode.
5. Change parameter 02 to “Ld” setting.
e LCD display should now read “landing door”.
If you have “Extra High Torque Door Operators” (see pg 7)
Set SLA controller to SL, no further commissioning of the SLA controller is required.
Commission the associated STD controller normally.
6. Change parameter 03 to match the channel of the adjacent car door. All the landing doors for
the front line must have the same channel as the front car door. e LCD display will show what
channel has been selected.
7. Change parameter 04 to address the landing door. Use “ADDRESS 01” for the lowest door in a
line of doors. Each additional landing door in line should be addressed in sequence (01, 02, 03
Etc). e LCD display will show what address has been selected.
8. Change parameter 10 to “Lr” setting. Press ENTER to begin learn cycle. Prior to learn, Landing
Door can be in any position. e learn cycle will fully close and then fully open. Once the
Landing Door is fully open, the learn cycle is complete and the ashing “LEARN” indicator on
the LCD will turn o.
OPEN CLOSE
_
+
ENTER
IND
AUTO
IND
AUTO
CLOSE