Torque is expressed as a percentage of nominal voltage for corresponding speed.
Parameter Description Range Landing Pre Set Car Pre Set
85
USER 2 options
00 = USER 2 POSITION
01 = USER 1 POSITION
02 = ZONE
03 = BUZZ / STROBE
04 = DOOR OPEN POSITION
05 = DOOR CLOSED POSITION
06 = AUX2 INPUT
07 = LCT (BRIDGE MODE ONLY P50=1)
08 = OVERLOAD
09 = OVERDUTY
10 = OVERLOAD / OVERDUTY
00-06 03 00
86 Retiring Cam Startup Torque 50-99 N/A 50
P87
SIMULTANEOUS OPERATION (INPUT 4 HIGH)
00 = CLOSE DIRECTION ONLY
01 = OPEN AND CLOSE DIRECTION
88
Car Door Aux2 Input Option
00 = Disabled
01 = Independent Car Door Operation with input ON
00-01 N/A 00
89
Momentary Door Open / Door Close Option
00 = Constant DO and DC operation
01 = Momentary DO and DC operation
00-01 N/A 00
93
Power Up landing door speed (unzoned only)
00 = learn speed until final open/close limit
01 = normal profile speed
00-01 01 N/A
94 Buzzer Output: 00 = Pulsing, 01 = Continuous 00-01 01 00
95 Close Input Buzzer Control: 00 = Disabled, 01 = Enabled 00-01 01 01
Hall Stop Button Input:
00 = Normally Open, 01 = Normally Closed
Power-Up Settings:
01 – Door Closed = 1, Door Open = 1;
02 – Door Closed = 1, Door Open = 0;
03 – Door Closed = 0, Door Open = 0;
If zoned, both Door Closed and Door Open = 0, regardless of selection.
Condition of outputs is established automatically after opening or closing
cycle
98 Show Cycle Counter 6 digits Cycle Counter Cycle Counter
Restore Factory Default Settings
00 – Exit without saving
01 – Restore all Motor parameters (#20 – 97)
02 – Restore all parameters (#2 – 97)
99 00-02 00 00
96 00-01 00 N/A
97 01-03 02 02