Motor Overload / Over Duty
OVERLOAD is ON solid when over current exists
at motor output
Check for shorts on motor line
Check for shorts to ground
Reset of overload is required; set parameter 01 to 01
and press ENTER to clear (must go to IND mode)
OVERLOAD is ashing when motor run time
exceeds duty
Let motor reset for 5 minutes
Over Duty does not require reset
Input Indicators
1 HDO - Hall door open button
2 HDC - Hall door closed button
3 ZNS - Floor Zone switch
4 EUD - Emergency Unlocking Device
5 STOP - hall door stop button
6 AUX1 - Not Used
7 AUX2 - Not Used
8 RE - Hall door light curtain input
(where provided)
Door Stop Sign
Door Stop Sign is ON
whenever motors are not
running
Door Stop Sign is OFF
when power is being
applied to motors
Landing Zone
Zone is ON solid when
elevator is at a oor with
retiring cam extended and
door unlocked
Input indicator 3 ZNS is
ON when door is ZONED
Zone and 3 are OFF
when doors are locked
and / or car is moving
between oors
Doors will not run if
ZONE is not made
Check ZNS and zone
switch
Emergency Unlocking Device
EUD is ON solid when EUD is STOP
at that oor
Input indicator 4 is ON when EUD is
STOP at that oor
EUD is ashing when EUD is STOP
at another oor on same channel
Doors will not run if any EUD is
STOP on the same channel
Radio Communication
Antenna is ON solid when elevator is at a oor and
door is ZONED
Antenna is ON solid when EUD is SET whether
door is ZONED or not
Antenna is OFF when elevator is not ZONED
For intermittent ashing in ZONE adjust channel
selection
Multiple Zone
MULTIZONE indicator is shown
when two or more landing door
controllers are ZONED on the same
channel
Check zone switches and ZNS inputs
at landings
Number Display
Number display show
encoder count (door
position)
Approximately 0-50
for landing door closed
position
Full count for open
position
May ash fault codes for
Peelle Use
7.5 LANDING DOOR LCD