user manual

4
N-0751M
199,900 BTU
12,000 BTU
202
4.0
0.65
0 - 2,000 Ft.
0 - 2,000 Ft.
(
0 - 610 m
)
199,900
168,000
168,000
2.0
2.0
0 - 2,000 ft.
(
0 - 610 m
)
2,000 - 4,500 ft
*
.
(
610 - 1,370 m
*
)
4.4" 4.4"
2.0
192,800
162,800
162,800
2,000 - 4,500 Ft.
2,000 - 4,500 Ft.
*
(
610 - 1,370 m
610 - 1,370 m
*
)
2.55"
10.5"
765
Natural
Gaz Naturel
4.
Before Installation
Checkup
Check the fixing brackets and vent pipe yearly for damage or wear. Replace if necessary.
DANGER
Do Not Use Equipment for Purposes Other Than Those Specified
Do not use for other than increasing the temperature of the water supply, as unexpected accidents
may occur as a result.
Check Water Supply Quality
If the water supply is hard, acidic or otherwise impure, treat the water with approved methods in
order to ensure full warranty coverage.
WARNING
CAUTION
Check the Gas
Check that the rating plate indicates the
correct type of gas.
Check that the gas supply line is sized for
199,900 Btuh for this unit.
Check the Power
The power supply required is 120V AC, at 60Hz.
Using the incorrect voltage may result in fire or electric shock.
Use Extreme Caution if Using With a Solar Pre-Heater
Using this unit with a solar pre-heater can lead to unpredictable output temperatures and
possibly scalding. If absolutely necessary, use mixing valves to ensure output temperatures do
not get to scalding levels. Do not use a solar pre-heater with the quick-connect multi-system.
[For indoor installation only]
WS-06-9012C_001_015_E_J.p65 07.1.5, 4:34 PMPage 4 Adobe PageMaker 6.5J/PPC