Use And Care Manual

GENERAL OPERATION
WARNING
Read the ENTIRE IMPORTANT SAFETY INFORMATION section at the begin-
ning of this manual including all text under subheadings therein before set up or use of
this product.
1. Switching on – press the switch
button (2) and hold it down.
2. Switching off – release the switch
button (2).
3. Switch lock (continuous operation).
a. Switching on: Press the button
switch (2), and then press the
switch lock button (3).
b. Switching off: Press and release the
switch button (2).
4. For use as a blower:
a. attach the nozzle (5) to the nozzle
retaining ring (8).
b. attach this assembly to the blowing
connector (1).
c. rotate clockwise to lock it in place.
5. For use as a vacuum:
a. attach the nozzle (5) to the suction
connector (4).
b. Attach the dust bag (6) to the
blowing connector (1).
c. After each use the dust bag must
be emptied. Unzip the bag and
empty its contents. If the bag
lling level is high, it will reduce the
suction power.
CARE & MAINTENANCE
1. Unplug the power cord from mains socket before any installation, adjustment,
repair, cleaning or maintenance.
2. Replacement of carbon brushes. Used (shorter than 5mm), burnt or broken
motor carbon brushes should be immediately replaced. Both carbon brushes
should always be replaced at the same time.
• Turn off the carbon brush plugs (7).
• Take out used carbon brushes and remove any carbon dust
using compressed air.
• Insert new carbon brushes. Carbon brushes should slide smoothly
into brush holders.
• Fasten the carbon brush plugs (7).
When the carbon brushes are removed, the device should be switched on for
approximately 1-2 minutes, so that carbon brushes can adapt to the motor.
Carbon brushes should be replaced only by a qualified person using original
spare parts.