User Manual

Use and Care Guide
Printed in USA 3 0213
SAFETY
DANGER
Indicates a hazard that WILL
result in serious injury or
death if precautions are not followed.
WARNING
Indicates a hazard MAY
cause serious injury or
death if precautions are not followed.
CAUTION
Indicates a hazard where
minor injury or product
damage may occur if precautions are not
followed.
OPERATION
Loading Product
Before storing perishables, turn unit on and allow
it to operate for a minimum of 24 hours to allow
temperatures to stabilize.
When loading items into the unit, do not block
internal louvers and fan guard openings or
performance will be decreased.
Checking Product Temperature
1. To accurately check the temperature of product
stored in the refrigerated compartment, insert
an accurate thermometer into a plastic
unbreakable bottle, partially lled with water.
Tighten bottle cap securely.
2. Place the bottle in the desired area for 24
hours. Refrain from opening the unit during
the testing period. After 24 hours, check
the temperature of the water. Adjust the
temperature accordingly using the procedures
on this page.
The unit is preset to achieve the recommended
temperature range when installed in a location
with a 70° ambient room temperature. The
following factors affect the internal temperature
of the unit:
• Temperature setting
Room temperature where installed
Number of times the door is opened and
closed
Length of time door is left open
Style of door installed
Door gasket seal and condition
Amount of time the internal light is illuminated
Installation in direct sunlight or near a heat
source
Interior Light
The unit is equipped with an interior light that
illuminates when the door is opened. The cabinet
also comes equipped with a manual light switch
for displaying the products through a glass door.
This is located on the back wall of the unit to the
left of the light; in the Signature Series, it is in front
on the control cradle.
Always ensure that the manual light switch is in
the OFF position before closing a solid wood or
stainless steel door. If manual light switch is left
on for an extended period of time, it may increase
the cabinet temperature, especially in the top
compartment, and cause the refrigeration system
to run harder.
Master Power Switch
Dual Zone products come equipped with a master
power switch located behind the louvered toe
kick. Remove the toe kick to turn power on or off
to the unit.
Digital Temperature Control
(Signature Series – 24” Dual-Zone)
SET
F
Figure 1. Digital Temperature Controller
Upper Compartment: To view the upper
compartment temperature, press and release the
DEFROST button (melting snow ake).
Lower Compartment: Display reading always
shows the lower compartment temperature.
Setpoint Display
Press and release the SET button; display will
read St1. Press SET again and the LOWER
Compartment setpoint will be displayed.
Press SET again; the display will read St2.
Press SET again and the UPPER Compartment